ArticleACS omega2023
Current Confinement Effect on the Performance of Blue Light Micro-LEDs with 10 μm Dimension.
Article in ACS omega, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The current confinement effect on the micro-LED (μLED) with a 10 μm dimension was simulated using SpeCLED software. In this study, three p-contact sizes were considered: 2 μm × 2 μm, 5 μm × 5 μm, and 8 μm × 8 μm dimensions for μLEDs with a 10 μm dimension. According to the simulation data, the highest external quantum efficiency (EQE) of 13.24% was obtained with a 5 μm × 5 μm contact size. The simulation data also showed that the μLEDs with narrow contact sizes experienced higher operating temperatures due to the current crowding effect. The experimental data revealed a red-shift effect in narrow contact sizes, indicating higher heat generation in those devices. As the contact sizes increased from 2 to 8 μm, the turn-on voltage decreased due to lower equivalent resistance. Additionally, the leakage current increased from 44 pA to 1.6 nA at a reverse voltage of -5 V. The study found that the best performance was achieved with a contact ratio of 0.5, which resulted in the highest EQE at 9.95%. This superior performance can be attributed to the better current confinement of the μLED compared to the μLED with a contact ratio of 0.8, resulting in lower leakage current and improved current spreading when compared to the μLED with a contact ratio of 0.2.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.