Evidence map›Paper›PMID 37779821›Full record

ArticleHardwareX2023

Low-cost, low-power, clockwork syringe pump.

Francis Pooke, Matthew Payne, Lui Holder-Pearson, Doug Heaton, Jake Campbell, J Geoffrey Chase

Abstract read
In one paragraph

Article in HardwareX, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Francis PookeDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Matthew PayneDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Lui Holder-PearsonDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Doug HeatonDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Jake CampbellDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
J Geoffrey ChaseDepartment of Mechanical Engineering, University of Canterbury, New Zealand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A low-cost ($120 NZD, $75 USD), low-power (1-year battery life), portable, and programmable syringe pump design is presented, which offers an alternative to high-cost commercial devices with limited battery life. Contrary to typical motor-driven syringe pumps, the design utilizes a compression spring coupled with a clockwork escapement mechanism to advance the syringe plunger. Full control over flow-rate and discrete (bolus) deliveries is achieved through actuation of a clockwork escapement using programmable, low-power electronics. The escapement mechanism allows the syringe plunger to advance a fixed linear distance, delivering a dose size of 0.001 ml in the configuration presented. The modular pump assembly is easily reconfigured for different applications by interchanging components to alter the minimum dose size. Testing to IEC 60601-2-24(2012), the average error of the clockwork syringe pump was 8.0%, 4.0%, and 1.9% for 0.001 ml, 0.002 ml, and 0.01 ml volumes, respectively. An overall mean error of 1.0% was recorded for a flow-rate of 0.01 ml h

Indexed as

EscapementInsulin pumpMicro-litre pumpProgrammableSpring-driven

Identifiers

PMID37779821
PMCPMC10540045

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked