Evidence map›Paper›PMID 37777691›Full record

ArticleAnnals of biomedical engineering2024

Personalized Numerical Cardiovascular Model with Weight Growth for Evaluating Pediatric Left Ventricular Assist Devices: Derivation from an Experimental Mock Circulatory Loop.

Phong Tran, Victor Tedesco, Simon Kiang, Shweta Karnik, David Nguyen, O H Frazier, Katharine H Fraser, Yaxin Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of biomedical engineering, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Phong TranInnovative Device and Engineering Applications Laboratory, Texas Heart Institute, Houston, TX, USA.
Victor TedescoInnovative Device and Engineering Applications Laboratory, Texas Heart Institute, Houston, TX, USA.
Simon KiangInnovative Device and Engineering Applications Laboratory, Texas Heart Institute, Houston, TX, USA.
Shweta KarnikBioengineering Department, Georgia Institute of Technology, Atlanta, GA, USA.
David NguyenInnovative Device and Engineering Applications Laboratory, Texas Heart Institute, Houston, TX, USA.
O H FrazierInnovative Device and Engineering Applications Laboratory, Texas Heart Institute, Houston, TX, USA.
Katharine H FraserDepartment of Mechanical Engineering, University of Bath, Bath, UK.
Yaxin WangInnovative Device and Engineering Applications Laboratory, Texas Heart Institute, Houston, TX, USA. ywang@texasheart.org.ORCID http://orcid.org/0000-0003-1903-1037

Funding

Development of a Fully-Implantable Ventricular Assist Device for Neonates and Children with Heart Failure - with Magnetic Levitation to Improve HemocompatibilityR01HL153538 · NHLBI · TEXAS HEART INSTITUTE · PI FRAZIER, O. H. · 2020 to 2023
$2.9M
NHLBI NIH HHS 1R01HL153538
6 · The paper itself

Abstract

Pediatric patients with heart failure have limited treatment options because of a shortage of donor hearts and compatible left ventricular assist devices (LVADs). To address this issue, our group is developing an implantable pediatric LVAD for patients weighing 5-20 kg, capable of accommodating different physiological hemodynamic conditions as patients grow. To evaluate LVAD prototypes across a wide range of conditions, we developed a numerical cardiovascular model, using data from a mock circulatory loop (MCL) and patient-specific elastance functions. The numerical MCL was validated against experimental MCL results, showing good agreement, with differences ranging from 0 to 11%. The numerical model was also tested under left heart failure conditions and showed a worst-case difference of 16%. In an MCL study with a pediatric LVAD, a pediatric dataset was obtained from the experimental MCL and used to tune the numerical MCL. Then, the numerical model simulated LVAD flow by using an HQ curve obtained from the LVAD's impeller. When the numerical MCL was validated against the experimental MCL, hemodynamic differences ranged between 0 and 9%. These findings suggest that the numerical model can replicate various physiological conditions and impeller designs, indicating its potential as a tool for developing and optimizing pediatric LVADs.

Indexed as

Heart-Assist DevicesHeart FailureHeart TransplantationChildHemodynamicsHumansModels, CardiovascularTissue DonorsComputational modelingHeart failureHemodynamicsLeft ventricular assist device

Identifiers

PMID37777691

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.