ArticleJournal of robotic surgery2023
Virtual assessment of coronal balance prior to bone resection with the MAKO robotic-assisted system accurately predicts final balance in TKA.
Article in Journal of robotic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.
- Precision soft tissue balance in robot-assisted total knee arthroplasty: a bibliometric and visualization analysis of dynamic gap equilibration.Journal of robotic surgery · 2026Pooled it
- Can a Total Knee System Providing 1 mm Increment of Polyethylene Insert Thickness Offer a Clinical Benefit?Medicina (Kaunas, Lithuania) · 2024Trial
- Predictive pre-resection robotic ligament balancing in total knee arthroplasty is accurate across surgeons and patient factors.Journal of robotic surgery · 2026Article
- Early outcomes and the learning curve of two domestically produced surgical robot systems with different operational philosophies for total knee arthroplasty.Journal of robotic surgery · 2026Article
- Real-World Outcomes of Robotic Total Knee Arthroplasty: Five Years' Experience in a Non-Academic Center.Journal of personalized medicine · 2025Article
- Dynamic joint balancing provides consistent gap prediction without a learning curve in robotic-assisted total knee arthroplasty.Journal of robotic surgery · 2025Article
- Grading medial compartment tightness among varus osteoarthritic knees during image-free robot-assisted total knee arthroplasty for optimized pre-resection gap balancing.Bone & joint open · 2025Article
- Comparison between ligament balancing and measured resection in robot-assisted total knee arthroplasty: a 2-year follow up cohort study.BMC musculoskeletal disorders · 2025Article
- Comparison of the efficacy and safety of MAKO robot-assisted total knee arthroplasty versus conventional manual total knee arthroplasty in uncomplicated unilateral total knee arthroplasty a single-centre retrospective analysis.International orthopaedics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Total knee arthroplasty (TKA) has traditionally relied on the surgeon's judgement and manual instruments to determine balance. The MAKO robotic system (Stryker Ltd, Kalamazoo, MI, USA) allows assessment of virtual compartmental gaps from CT-derived bone models intra-operatively as a predictor of soft tissue balance that will be achieved, prior to any bony resection. This study aims to assess the accuracy of this pre-resection balancing technique in determining the resultant final soft tissue balance of the TKA. A consecutive prospective cohort of 2027 Robotic-Assisted TKAs (RATKA) were performed between January'17 and March'22. Osteophytes were removed; initial virtual gaps on the virtual bone model were measured at 10° and 90° of flexion prior to bone resections. Optimization of the virtual component positions was then made and final pre-resection gaps were measured. The gaps were then re-assessed post-implantation and compared to the final pre-resection values. Virtual balancing in extension within 1 mm was achieved in 95% of cases. Of those, 98% maintained coronal balance within 1 mm after implantation, with 1.5% requiring a coronal plane soft tissue release. Inability to virtually balance a TKA within 2 mm prior to bone resection resulted in a soft tissue release in 44.4% of cases. The absolute values of the final gaps achieved were a mean of 1.3 mm greater than virtual gaps. The ability to balance a knee on the virtual bone model prior to bone resection, in conjunction with robotic-assisted execution of TKA, consistently achieves a balanced knee after component implantation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.