Evidence map›Paper›PMID 37775600›Full record

ArticleInsights into imaging2023

Core and penumbra estimation using deep learning-based AIF in association with clinical measures in computed tomography perfusion (CTP).

Sukhdeep Singh Bal, Fan-Pei Gloria Yang, Nai-Fang Chi, Jiu Haw Yin, Tao-Jung Wang, Giia Sheun Peng, Ke Chen, Ching-Chi Hsu, Chang-I Chen

Abstract read
In one paragraph

Article in Insights into imaging, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Sukhdeep Singh BalDepartment of Mathematical Sciences, University of Liverpool, Liverpool, Merseyside, UK.
Fan-Pei Gloria YangCenter for Cognition and Mind Sciences, National Tsing Hua University, Hsinchu, Taiwan. hbmyang@gmail.com.
Nai-Fang ChiNeurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan.
Jiu Haw YinDepartment of Neurology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan.
Tao-Jung WangDepartment of Computer Science, National Yang Ming Chiao Tung University, Hsinchu, Taiwan.
Giia Sheun PengDepartment of Neurology, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan.
Ke ChenDepartment of Mathematical Sciences, University of Liverpool, Liverpool, Merseyside, UK.
Ching-Chi HsuBoard of Directors, Wizcare Medical Corporation Aggregate, Taichung, Taiwan.
Chang-I ChenDepartment of Medical Management, Taipei Medical University, Taipei, Taiwan.

Funding

Ministry of Science and Technology, Taiwan 110-2622-8-038-003-SB
6 · The paper itself

Abstract

objectivesTo investigate whether utilizing a convolutional neural network (CNN)-based arterial input function (AIF) improves the volumetric estimation of core and penumbra in association with clinical measures in stroke patients.

methodsThe study included 160 acute ischemic stroke patients (male = 87, female = 73, median age = 73 years) with approval from the institutional review board. The patients had undergone CTP imaging, NIHSS and ASPECTS grading. convolutional neural network (CNN) model was trained to fit a raw AIF curve to a gamma variate function. CNN AIF was utilized to estimate the core and penumbra volumes which were further validated with clinical scores.

resultsPenumbra estimated by CNN AIF correlated positively with the NIHSS score (r = 0.69; p < 0.001) and negatively with the ASPECTS (r =  - 0.43; p < 0.001). The CNN AIF estimated penumbra and core volume matching the patient symptoms, typically in patients with higher NIHSS (> 20) and lower ASPECT score (< 5). In group analysis, the median CBF < 20%, CBF < 30%, rCBF < 38%, Tmax > 10 s, Tmax > 10 s volumes were statistically significantly higher (p < .05).

conclusionsWith inclusion of the CNN AIF in perfusion imaging pipeline, penumbra and core estimations are more reliable as they correlate with scores representing neurological deficits in stroke. CRITICAL RELEVANCE STATEMENT: With CNN AIF perfusion imaging pipeline, penumbra and core estimations are more reliable as they correlate with scores representing neurological deficits in stroke.

Indexed as

Arterial input functionCoreIschemic strokePenumbraPerfusion parameters

Identifiers

PMID37775600
PMCPMC10541385

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.