Evidence map›Paper›PMID 37775594›Full record

ArticleInternational journal of legal medicine2024

Comparison of nine extraction methods for bacterial identification using the ONT MinION sequencer.

Kari A Graham, Javier Gomez, Todd P Primm, Rachel Houston

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of legal medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Kari A GrahamDepartment of Forensic Science, College of Criminal Justice, Sam Houston State University, 1003 Bowers Blvd., Huntsville, TX, 77340-2525, USA.ORCID http://orcid.org/0000-0003-0767-1459
Javier GomezDepartment of Biological Sciences, College of Science and Engineering Technology, Sam Houston State University, 2000 Ave I, Huntsville, TX, 77341, USA.
Todd P PrimmDepartment of Biological Sciences, College of Science and Engineering Technology, Sam Houston State University, 2000 Ave I, Huntsville, TX, 77341, USA.
Rachel HoustonDepartment of Forensic Science, College of Criminal Justice, Sam Houston State University, 1003 Bowers Blvd., Huntsville, TX, 77340-2525, USA. rmh034@shsu.edu.ORCID http://orcid.org/0000-0001-9833-6837

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The Anthrax mailings bioterrorism attack in 2001 revealed the need for universal and rapid microbial forensic analyses on unknown biological evidence. However, the gold standard for bacterial identification includes culturing isolates, which is laborious. Molecular approaches for bacterial identification revolve around 16S ribosomal gene sequencing using Sanger or next generation sequencing (NGS) platforms, but these techniques are laboratory-based and can also be time-consuming. The Oxford Nanopore Technologies (ONT) MinION sequencer can generate long read lengths that span the entire bacterial 16S rRNA gene and accurately identify the species level. This platform can be used in the field, allowing on-site evidence analysis. However, it requires higher quantities of pure DNA compared to other sequencing platforms; thus, the extraction method for bacterial DNA is critical for downstream analysis, which to date are tailored toward a priori knowledge of the species' taxonomic grouping. During an attack, the investigative team may not know what species they are handling; therefore, identifying an extraction method that can handle all bacterial groups and generate clean DNA for the MinION is useful for microbial forensic analysis. The purpose of this study was to identify a "universal" extraction method that can be coupled with ONT MinION sequencing for use in forensic situations for rapid identification. It also evaluated the cloud-based data analysis software provided by ONT, EPI2ME. No "universal" extraction method was identified as optimal for downstream MinION sequencing. However, the DNeasy PowerSoil Kit and Noda et al. Chelex-100 method gave comparable sequencing results and could be used as rapid extraction techniques. This study showed that the ONT 16S Barcoding Kit 1-24 coupled with the 16S FASTQ workflow might not be the best for use in forensic situations where species-level identification needs to be obtained, as most alignments were approximately 89% accurate. In all seven test organisms and nine extraction methods, accurate species identification was only obtained in 63% of the cases.

Indexed as

NanoporesBacteriaDNAHigh-Throughput Nucleotide SequencingHumansRNA, Ribosomal, 16SSequence Analysis, DNADNARNA, Ribosomal, 16S16S rRNA sequencingBacterial DNA extractionBioterrorismMicrobial forensics

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.