Evidence map›Paper›PMID 37773551›Full record

ArticleJA clinical reports2023

Effect of averaging time and respiratory pause time on the measurement of acoustic respiration rate monitoring.

Jun Honda, Masahiro Murakawa, Satoki Inoue

Abstract read
In one paragraph

Article in JA clinical reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jun HondaDepartment of Anesthesiology, Fukushima Medical University Hospital, 1 Hikarigaoka, Fukushima City, Fukushima, 960-1295, Japan. j.honda1984@gmail.com.ORCID http://orcid.org/0000-0002-2655-0436
Masahiro MurakawaDepartment of Anesthesiology, Iwase General Hospital, 20, Kitamachi, Sukagawa City, Fukushima, 962-8503, Japan.
Satoki InoueDepartment of Anesthesiology, Fukushima Medical University Hospital, 1 Hikarigaoka, Fukushima City, Fukushima, 960-1295, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAcoustic respiration rate (RRa) monitoring is a method of continuously measuring respiratory rate using a signal from an acoustic transducer placed over the airway. The purpose of the present study is to examine how the averaging time and respiratory pause time settings of an RRa monitor affect the detection time of sudden respiratory rate changes.

methodsA total of 40 healthy adult volunteers were included in the study. First, we measured the apnea detection time (apnea test) by dividing them into two groups (N = 20 each), one with a respiratory pause time setting of 20 s and the other with 40 s. Each group performed two apnea tests with an averaging time setting of 10 and 30 s. Next, we measured the tachypnea detection time (tachypnea test) for half of the subjects (N = 20) with two averaging time settings of 10 and 30 s. For each test, three measurements were taken, and the average of the three measurements was recorded.

resultsThere was no significant difference in the apnea detection time between the averaging time set at 10 and 30 s regardless of whether the respiratory pause time was set at 20 or 40 s. However, the apnea detection time was significantly shorter with the respiratory pause time of 20 s than 40 s, regardless of whether the averaging time was set at 10 or 30 s (p < 0.001). The tachypnea detection time was shorter with the averaging time of 10 s than 30 s (p < 0.001). Furthermore, the apnea detection time and tachypnea detection time were much longer than the actual settings.

conclusionsThe results of the current study show that in the measurement of RRa, the apnea detection time is more affected by the respiratory pause time setting than the averaging time setting; however, the tachypnea detection time is significantly affected by the averaging time setting.

Indexed as

Acoustic respiration rate monitoringApneaAveraging timeRespiratory pause timeTachypnea

Identifiers

PMID37773551
PMCPMC10541352

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.