Evidence map›Paper›PMID 37773534›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Patient specific instrumentation in ACL reconstruction: a proof-of-concept cadaver experiment assessing drilling accuracy when using 3D printed guides.

Mark J M Zee, Peter A J Pijpker, Joep Kraeima, Alain R Viddeleer, Ronald L Diercks

Open access · hybridAbstract read
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Mark J M ZeeDepartment of Orthopedic Surgery, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, PO Box 30.001, 9700RB, Groningen, The Netherlands. m.j.m.zee@umcg.nl.ORCID http://orcid.org/0000-0003-1882-0261
Peter A J Pijpker3D Lab, Department of Orthopedic Surgery, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, PO Box 30.001, 9700RB, Groningen, The Netherlands.
Joep Kraeima3D Lab, Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, PO Box 30.001, 9700RB, Groningen, The Netherlands.
Alain R ViddeleerMedical Imaging Center, Department of Radiology, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, PO Box 30.001, 9700RB, Groningen, The Netherlands.
Ronald L DiercksDepartment of Orthopedic Surgery, University of Groningen, University Medical Centre Groningen, Hanzeplein 1, PO Box 30.001, 9700RB, Groningen, The Netherlands.
University Medical Center Groningen · NL

Funding

Samenwerkingsverband Noord-Nederland OPSNN0175
6 · The paper itself

Abstract

introductionAccurate positioning of the femoral tunnel in ACL reconstruction is of the utmost importance to reduce the risk of graft failure. Limited visibility during arthroscopy and a wide anatomical variance attribute to femoral tunnel malposition using conventional surgical techniques. The purpose of this study was to determine whether a patient specific 3D printed surgical guide allows for in vitro femoral tunnel positioning within 2 mm of the planned tunnel position. MATERIALS AND

methodsA patient specific guide for femoral tunnel positioning in ACL reconstruction was created for four human cadaveric knee specimens based on routine clinical MRI data. Fitting properties were judged by two orthopedic surgeons. MRI scanning was performed both pre- and post-procedure. The planned tunnel endpoint was compared to the actual drilled femoral tunnel.

resultsThis patient specific 3D printed guide showed a mean deviation of 5.0 mm from the center of the planned femoral ACL origin.

conclusionIn search to improve accuracy and consistency of femoral tunnel positioning in ACL reconstruction, the use of a patient specific 3D printed surgical guide is a viable option to explore further. The results are comparable to those of conventional techniques; however, further design improvements are necessary to improve accuracy and enhance reproducibility.

Indexed as

Anterior Cruciate LigamentAnterior Cruciate Ligament ReconstructionCadaverFemurHumansKnee JointPrinting, Three-DimensionalReproducibility of ResultsTibiaACL reconstructionAnatomicFemoral tunnelPatient specific instrument

Identifiers

PMID37773534
PMCPMC10774211
OpenAlexW4387186615

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.