ArticleEuropean journal of radiology open2023
Automated advanced imaging in acute ischemic stroke. Certainties and uncertainties.
Article in European journal of radiology open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 10 citations in OpenAlex.
- Target mismatch criteria in acute ischemic stroke patients with distal-medium vessel occlusion.European stroke journal · 2026Article
- Evaluation of a Deep Learning Tool for Detecting Large Vessel Occlusion and Intracranial Hemorrhage on Noncontrast Computed Tomography Scans.Stroke (Hoboken, N.J.) · 2025Article
- Prediction of late seizures after ischemic stroke using cognitive scores.BMC neurology · 2025Article
- Target mismatch criteria in acute ischemic stroke patients with distal-medium vessel occlusion.European stroke journal · 2025Article
- Quantitative Evaluation of Ischemic Core Volume in GE's CT Perfusion Imaging Analysis Software and Its Relationship to Alberta Stroke Program Early CT Score.Journal of neuroendovascular therapy · 2025Article
- Association between Cerebral Blood Volume Index and Excellent Reperfusion in Acute Ischemic Stroke Patients Undergoing Mechanical Thrombectomy.Current neurovascular research · 2025Article
- Current Stroke Solutions Using Artificial Intelligence: A Review of the Literature.Brain sciences · 2024Review
- Defining Large Core Infarction: Comparing the Accuracy of Non-Contrast CT ASPECTS Versus CT Perfusion Core Volume.Journal of neuroimaging : official journal of the American Society of NeuroimagingArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this is study was to review pearls and pitfalls of advanced imaging, such as computed tomography perfusion and diffusion-weighed imaging and perfusion-weighted imaging in the selection of acute ischemic stroke (AIS) patients suitable for endovascular treatment (EVT) in the late time window (6-24 h from symptom onset). Advanced imaging can quantify infarct core and ischemic penumbra using specific threshold values and provides optimal selection parameters, collectively called target mismatch. More precisely, target mismatch criteria consist of core volume and/or penumbra volume and mismatch ratio (the ratio between total hypoperfusion and core volumes) with precise cut-off values. The parameters of target mismatch are automatically calculated with dedicated software packages that allow a quick and standardized interpretation of advanced imaging. However, this approach has several limitations leading to a misclassification of core and penumbra volumes. In fact, automatic software platforms are affected by technical artifacts and are not interchangeable due to a remarkable vendor-dependent variability, resulting in different estimate of target mismatch parameters. In addition, advanced imaging is not completely accurate in detecting infarct core, that can be under- or overestimated. Finally, the selection of candidates for EVT remains currently suboptimal due to the high rates of futile reperfusion and overselection caused by the use of very stringent inclusion criteria. For these reasons, some investigators recently proposed to replace advanced with conventional imaging in the selection for EVT, after the demonstration that non-contrast CT ASPECTS and computed tomography angiography collateral evaluation are not inferior to advanced images in predicting outcome in AIS patients treated with EVT. However, other authors confirmed that CTP and PWI/DWI postprocessed images are superior to conventional imaging in establishing the eligibility of patients for EVT. Therefore, the routine application of automatic assessment of advanced imaging remains a matter of debate. Recent findings suggest that the combination of conventional and advanced imaging might improving our selection criteria.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials