Evidence map›Paper›PMID 37766760›Full record

ArticleBeyoglu eye journal2023

Agreement among Goldmann Applanation Tonometer, Easyton Transpalpebral Tonometer, Tonopen, and Icare in Patients with Keratoconus.

Merve Beyza Yildiz, Alev Ozcelik Kose, Gokhan Celik, Osman Kizilay, Serhat Imamoglu, Elvin Yildiz

Open access · diamondAbstract read
In one paragraph

Article in Beyoglu eye journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Intraocular pressure measurement in keratoconus: a narrative review.International journal of ophthalmology · 2026
    Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Merve Beyza YildizDepartment of Ophthalmology, Haydarpasa Numune Training and Research Hospital, Istanbul, Türkiye.
Alev Ozcelik KoseDepartment of Ophthalmology, Haydarpasa Numune Training and Research Hospital, Istanbul, Türkiye.
Gokhan CelikDepartment of Ophthalmology, Zeynep Kamil Maternity and Children Hospital, Istanbul, Türkiye.
Osman KizilayDepartment of Ophthalmology, Zeynep Kamil Maternity and Children Hospital, Istanbul, Türkiye.
Serhat ImamogluDepartment of Ophthalmology, Haydarpasa Numune Training and Research Hospital, Istanbul, Türkiye.
Elvin YildizDepartment of Ophthalmology, Haydarpasa Numune Training and Research Hospital, Istanbul, Türkiye.
Haydarpaşa Numune Eğitim ve Araştırma Hastanesi · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: The objective of the study is to evaluate the agreement between Goldmann applanation tonometer (GAT) and Easyton transpalpebral tonometer, Tonopen, and Icare in patients with Keratoconus. Methods: This cross-sectional study included 46 eyes of 26 patients with keratoconus. Intraocular pressure (IOP) is measured using easyton, icare, tonopen, and GAT. Measurements were compared and the influences of corneal topographic variables on IOP measurement were evaluated. Bland-Altman plots were used for assessing agreement between different tonometers. Results: The mean age of the participants was 24.08±6.76 (range, 18-47) years (15 males and 11 females). The highest of the mean IOP values measured with different tonometers was obtained with Easyton (12.33±1.65), followed by Tonopen (11.59±2.17), GAT (10.67±1.52), and Icare (10.04±2.33). The mean IOP value measured with Easyton was significantly higher than that measured with GAT (p<0.001). There was no significant difference between GAT and either Tonopen (p=0.154) or Icare measurements (p=0.732). There was no significant difference between Tonopen and Easyton measurements (p=0.421). Icare measurements were correlated with central corneal thickness and keratometric values. GAT measurements were correlated with only Kmax. Thirty-eight (82.6%) of the differences were within the agreement limits (assumed clinically important deviation of up to ±2 mmHg) of GAT and Tonopen, 73.9% (n=34) were within the agreement limits of GAT and Icare, and 78.3% (n=36) were within the agreement limits of GAT and Easyton. Conclusion: Compared with GAT, the gold standard method, Easyton IOP readings were higher, while both Tonopen and Icare readings were similar to GAT. All three tonometers showed acceptable agreement with the GAT, however, Tonopen showed the greatest agreement.

Indexed as

Easyton transpalpebral tonometergoldmann applanation tonometericareintraocular pressurekeratoconustonopen

Identifiers

PMID37766760
PMCPMC10521132
OpenAlexW4387110595

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.