Evidence map›Paper›PMID 37765760›Full record

ArticleSensors (Basel, Switzerland)2023

Temperature-Compensated Solution Concentration Measurements Using Photonic Crystal Fiber-Tip Sensors.

Mildred S Cano-Velázquez, Arthur L Hendriks, Luca Picelli, Rene P J van Veldhoven, Andrea Fiore

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Mildred S Cano-VelázquezDepartment of Applied Physics and Science Education, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-9128-0161
Arthur L HendriksDepartment of Applied Physics and Science Education, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-9850-3831
Luca PicelliDepartment of Applied Physics and Science Education, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-7674-0318
Rene P J van VeldhovenDepartment of Applied Physics and Science Education, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.
Andrea FioreDepartment of Applied Physics and Science Education, Eindhoven University of Technology, 5600 MB Eindhoven, The Netherlands.ORCID 0000-0002-6430-4359
Eindhoven University of Technology · NL

Funding

Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO) under Toegepaste en Technische Wetenschappen (TTW) 18477Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO) Zwaartekracht Research Center for Integrated Nanophotonics
6 · The paper itself

Abstract

We demonstrate fiber optic sensors with temperature compensation for the accurate measurement of ethanol concentration in aqueous solutions. The device consists of two photonic crystal (PhC) fiber-tip sensors: one measures the ethanol concentration via refractive index (RI) changes and the other one is isolated from the liquid for the independent measurement of temperature. The probes utilize an optimized PhC design providing a Lorentzian-like, polarization-independent response, enabling a very low imprecision (pm-level) in the wavelength determination. By combining the information from the two probes, it is possible to compensate for the effect that the temperature has on the concentration measurement, obtaining more accurate estimations of the ethanol concentration in a broad range of temperatures. We demonstrate the simultaneous and single-point measurements of temperature and ethanol concentration in water, with sensitivities of 19 pm/°C and ∼53 pm/%, in the ranges of 25 °C to 55 °C and 0 to 50% (at 25 °C), respectively. Moreover, a maximum error of 1.1% in the concentration measurement, with a standard deviation of ≤0.8%, was obtained in the entire temperature range after compensating for the effect of temperature. A limit of detection as low as 0.08% was demonstrated for the concentration measurement in temperature-stable conditions.

Indexed as

chemical sensorsin-line measurementsoptical fiber sensorsphotonic crystals

Identifiers

PMID37765760
PMCPMC10537503
OpenAlexW4386476017

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked