Evidence map›Paper›PMID 37765571›Full record

ReviewPolymers2023

Tracking Resistance in Polymeric Insulation Materials for High-Voltage Electrical Mobility Applications Evaluated by Existing Test Methods: Identified Research Needs.

Jordi-Roger Riba, Manuel Moreno-Eguilaz, Santiago Bogarra

Abstract readReview
In one paragraph

Review in Polymers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jordi-Roger RibaElectrical Engineering Department, Universitat Politècnica de Catalunya, 08222 Terrassa, Spain.ORCID 0000-0001-8774-2389
Manuel Moreno-EguilazElectrical Engineering Department, Universitat Politècnica de Catalunya, 08222 Terrassa, Spain.ORCID 0000-0001-6086-7034
Santiago BogarraElectrical Engineering Department, Universitat Politècnica de Catalunya, 08222 Terrassa, Spain.ORCID 0000-0002-2006-1156

Funding

Generalitat de Catalunya 2021 SGR 00392Ministerio de Ciencia e Innovación de España PID2020-114240RB-I00
6 · The paper itself

Abstract

With the increasing electrification of the transportation and mobility sectors, polymer insulation materials are inevitably exposed to harsher environments, including exposure to contamination, wide temperature ranges, operation at higher voltages and switching frequencies, and low-pressure environments. This paper reviews the tests to characterize the polymeric materials used in insulation systems for electric mobility applications, focusing on resistance to tracking. This paper also reports on the limitations of existing standard test methods and identifies the challenges and research needs to meet the increasing demands of the electric mobility industry. To this end, an evaluation of the scientific and technological state of the art is carried out through the analysis of theses, research articles, technical reports, manufacturers' datasheets, international standards, and white papers.

Indexed as

electrical dischargesinsulation degradationinsulation polymer materialstracking resistance

Identifiers

PMID37765571
PMCPMC10536208

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.