ArticleMicromachines2023
A Hybrid Strategy for Profile Measurement of Micro Gear Teeth.
Article in Micromachines, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Design, Manufacturing, Tribology, and Performance of Microgears and Microgear Trains: A Critical Review of Mechanical Power Transmission at the Microscale.Micromachines · 2026Review
- High-Density Arrayed Spectrometer with Microlens Array Grating for Multi-Channel Parallel Spectral Analysis.Sensors (Basel, Switzerland) · 2025Article
- High-Precision Chromatic Confocal Technologies: A Review.Micromachines · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
A hybrid strategy is proposed to meet the challenge of obtaining the profile of micro gear teeth with a small modulus. Firstly, the contact probe segmentally obtained the falling flank profiles with an auxiliary lifting mechanism to avoid interference when it climbs on the rising slope. Then, the noncontact chromatic confocal displacement sensor efficiently acquired the gear peak positions to carry out the two-point error separation with the gear peak positions from the probe measurement. Finally, actual experiments were carried out to obtain the profile of a harmonic drive flexspline. Compared with the commercial ultraprecise profiler, the proposed method provides measurement results with a deviation of less than 20 μm. In conclusion, the hybrid strategy is feasible and accurate for drawing the micro gear teeth profile without any collision between the measuring probes and the measured workpiece.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.