Evidence map›Paper›PMID 37763052›Full record

ArticleJournal of personalized medicine2023

Accuracy of Positioning and Risk Factors for Malpositioning Custom-Made Femoral Stems in Total Hip Arthroplasty-A Retrospective Multicenter Analysis.

Philip Mark Anderson, Tizian Heinz, Dominik Rak, Jörg Arnholdt, Boris Michael Holzapfel, Silke Dorsch, Manuel Weißenberger, Rüdiger von Eisenhart-Rothe, Max Jaenisch, Max Ertl and 4 more

Abstract read
In one paragraph

Article in Journal of personalized medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Philip Mark AndersonDepartment of Orthopedics, König-Ludwig-Haus, University of Würzburg, Brettreichstraße 11, 97070 Wuerzburg, Germany.
Tizian HeinzDepartment of Orthopedics, König-Ludwig-Haus, University of Würzburg, Brettreichstraße 11, 97070 Wuerzburg, Germany.
Dominik RakDepartment of Orthopedics, König-Ludwig-Haus, University of Würzburg, Brettreichstraße 11, 97070 Wuerzburg, Germany.
Jörg ArnholdtDepartment of Orthopedic Surgery, Klinikum Grosshadern, Ludwig-Maximilians-University of Munich, Marchioninistraße 15, 81377 Munich, Germany.
Boris Michael HolzapfelDepartment of Orthopedic Surgery, Klinikum Grosshadern, Ludwig-Maximilians-University of Munich, Marchioninistraße 15, 81377 Munich, Germany.
Silke DorschDepartment of Orthopedics, König-Ludwig-Haus, University of Würzburg, Brettreichstraße 11, 97070 Wuerzburg, Germany.
Manuel WeißenbergerDepartment of Orthopedics, König-Ludwig-Haus, University of Würzburg, Brettreichstraße 11, 97070 Wuerzburg, Germany.ORCID 0000-0003-3551-3204
Rüdiger von Eisenhart-RotheDepartment of Orthopaedics and Sports Orthopaedics, Klinikum Rechts der Isar, School of Medicine, Technical University of Munich, Ismaninger Straße 22, 81675 Munich, Germany.
Max JaenischDepartment of Orthopedics and Trauma Surgery, University Hospital Bonn, Venusberg Campus 1, 53127 Bonn, Germany.ORCID 0000-0001-5998-0224
Max ErtlDepartment of Orthopaedic Surgery, Klinikum Rechts der Isar, Technical University of Munich, Ismaninger Straße 22, 81675 Munich, Germany.
Michael WagnerDepartment of Orthopaedics and Trauma Surgery, Klinikum Nürnberg Campus Süd, Paracelsus Medical University, Breslauer Straße 201, 90472 Nürnberg, Germany.
Henning WindhagenDepartment of Orthopaedic Surgery, Annastift Hannover, Medical School Hannover, Borries Str. 1-6, 30625 Hannover, Germany.
Maximilian RudertDepartment of Orthopedics, König-Ludwig-Haus, University of Würzburg, Brettreichstraße 11, 97070 Wuerzburg, Germany.ORCID 0000-0003-4982-6594
Axel JakuscheitDepartment of Orthopedics, König-Ludwig-Haus, University of Würzburg, Brettreichstraße 11, 97070 Wuerzburg, Germany.ORCID 0000-0001-9362-2914

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Total hip arthroplasty (THA) is commonly performed using off-the-shelf implants. In the case of a severe mismatch between the anatomy of the proximal femur and the geometry of the stem, the use of custom-made stems might become necessary. The goal of this study was to investigate the precision of the implantation of custom-made stems of one manufacturer (CTX stem, AQ Implants) and to determine risk factors for malpositioning. All patients receiving a custom-made CTX stem between 2014 and 2020 at six high-volume academic centers were retrospectively recruited. The achieved position of the stem, as determined by stem version, stem coronal angle, and implantation depth on radiographs, was compared to the plan. The influence of radiographic and demographic parameters on the position was investigated. The results revealed a high variability of the achieved implant position in relation to the preoperative plan. While the stem coronal angle only differed slightly from the intended position, the stem version and the implantation depth showed a high frequency and amount of deviation. Right stems showed significantly higher positions than planned. Surgeons must be aware of this potential problem when implanting custom-made stems.