Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors.

Zhicheng Jin, Rongrong Huang, Paul Christensen, Roger L Bertholf, Xin Yi

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Zhicheng JinDepartment of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA.ORCID 0000-0003-2770-9549
Rongrong HuangDepartment of Pathology and Immunology, Baylor College of Medicine, Harris Health System Ben Taub Hospital, Houston, TX 77030, USA.ORCID 0000-0003-4045-5299
Paul ChristensenDepartment of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA.
Roger L BertholfDepartment of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA.ORCID 0000-0002-7550-5148
Xin YiDepartment of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, TX 77030, USA.
Cornell University · USBaylor College of Medicine · USMethodist Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAn accurate measurement of the glomerular filtration rate (GFR) is essential for detecting renal insufficiency in living kidney donors. Iohexol is a "near-ideal" exogenous filtration marker for GFR measurements that has attracted increasing interest in clinical practice because it is non-toxic, non-radioactive, readily available, and easy to measure. In this study, we aimed to set up a laboratory test to conveniently assess the plasma clearance of iohexol in living kidney donors.

methodsA workflow was established in the institution's infusion clinic to administer iohexol and to collect three timed blood samples from renal transplant donors. Iohexol was thereafter measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The serum proteins were precipitated and the supernatant containing iohexol was diluted prior to the LC-MS/MS analysis. The LC-MS/MS method was developed on a Thermo Vanquish UHPLC coupled with a TSQ Endura triple quadruple mass spectrometer with a total run time of 2.5 min. The analytical performance of the method was assessed.

resultsThe LC-MS/MS method demonstrated a good analytical performance. To calculate the iohexol clearance rate and the GFR, automated data integration and a result calculation were accomplished by using a custom Python script. Automated result reporting was achieved using a laboratory informatics system (LIS) vendor's direct media interface.

conclusionsWe developed and implemented a laboratory test to assess the plasma clearance of iohexol. A workflow was established in the hospital to reliably measure the GFR in living kidney donors, with a potential to be further expanded into other areas where an accurate GFR measurement is needed.

Indexed as

glomerular filtration rateLC-MS/MSplasma iohexol clearance

Identifiers

PMID37762993
PMCPMC10532236
OpenAlexW4386894563

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.