Evidence map›Paper›PMID 37761669›Full record

ArticleHealthcare (Basel, Switzerland)2023

Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report.

José Henrique Lopo Barros, Murilo Navarro de Oliveira, Igor Oliveiros Cardoso, Guilherme José Pimentel Lopes de Oliveira, Célio Jesus do Prado, Flávio Domingues Das Neves

Open access · goldAbstract readCase Reports
In one paragraph

Article in Healthcare (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

José Henrique Lopo BarrosDepartment of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Uberlandia 38405-320, MG, Brazil.
Murilo Navarro de OliveiraSchool of Dentistry, University Center-UNIFAE, São João da Boa Vista 13870-377, SP, Brazil.
Igor Oliveiros CardosoCollege of Dentistry, University Center of Triangle (UNITRI), Uberlandia 38411-849, MG, Brazil.
Guilherme José Pimentel Lopes de OliveiraDepartment of Periodontology and Implantology, School of Dentistry, Federal University of Uberlandia, Uberlandia 38405-320, MG, Brazil.
Célio Jesus do PradoDepartment of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Uberlandia 38405-320, MG, Brazil.
Flávio Domingues Das NevesDepartment of Occlusion, Fixed Prosthodontics and Dental Materials, School of Dentistry, Federal University of Uberlandia, Uberlandia 38405-320, MG, Brazil.
Universidade Federal de Uberlândia · BRCentro Universitário do Triângulo · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study presented a rehabilitation option for malpositioned implants; this involved obtaining their position and inclination through intraoral scanning, and producing a customized abutment with CAD/CAM technology. The patient in this case report presented a root fracture in tooth 21 and was subjected to extraction, implant installation, and immediate provisional prosthesis. The implant was installed with a distal inclination due to anatomical limitations. After osseointegration, an intraoral scanning transfer provided a digital model (file extension .stl), which reproduced the implant's position and inclination. Then, the file was sent so that a customized abutment (CAD/CAM) could be manufactured, promoting the final rehabilitation of the case; this allowed for good hygiene, load distribution in the dynamic interocclusal relationship, and favorable esthetics, whereas many would otherwise recommend implant removal. The result presented lower costs, a shorter time frame, and a lower morbidity for the patient.

Indexed as

CAD/CAM technologycustomized abutment (CAD/CAM)dental implantdigital flowtooth fracture

Identifiers

PMID37761669
PMCPMC10530779
OpenAlexW4386475643

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked