Evidence map›Paper›PMID 37761230›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Automated Intracranial Clot Detection: A Promising Tool for Vascular Occlusion Detection in Non-Enhanced CT.

Ricarda Schwarz, Georg Bier, Vera Wilke, Carlo Wilke, Oliver Taubmann, Hendrik Ditt, Johann-Martin Hempel, Ulrike Ernemann, Marius Horger, Georg Gohla

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Ricarda SchwarzDepartment of Diagnostic and Interventional Radiology, Eberhard Karls University of Tuebingen, D-72076 Tuebingen, Germany.
Georg BierDepartment of Diagnostic and Interventional Neuroradiology, Eberhard Karls University of Tuebingen, D-72076 Tuebingen, Germany.
Vera WilkeDepartment of Neurology & Stroke, Eberhard Karls University of Tuebingen, D-72076 Tuebingen, Germany.
Carlo WilkeDivision Translational Genomics of Neurodegenerative Diseases, Hertie Institute for Clinical Brain Research, Center of Neurology, University of Tuebingen, D-72076 Tuebingen, Germany.
Oliver TaubmannSiemens Healthcare GmbH, Computed Tomography, D-91301 Forchheim, Germany.ORCID 0000-0001-5668-8092
Hendrik DittSiemens Healthcare GmbH, Computed Tomography, D-91301 Forchheim, Germany.
Johann-Martin HempelDepartment of Diagnostic and Interventional Neuroradiology, Eberhard Karls University of Tuebingen, D-72076 Tuebingen, Germany.ORCID 0000-0002-9647-5136
Ulrike ErnemannDepartment of Diagnostic and Interventional Neuroradiology, Eberhard Karls University of Tuebingen, D-72076 Tuebingen, Germany.
Marius HorgerDepartment of Diagnostic and Interventional Radiology, Eberhard Karls University of Tuebingen, D-72076 Tuebingen, Germany.
Georg GohlaDepartment of Diagnostic and Interventional Neuroradiology, Eberhard Karls University of Tuebingen, D-72076 Tuebingen, Germany.ORCID 0000-0001-7596-5139
University of Tübingen · DESiemens Healthineers (Germany) · DEGerman Center for Neurodegenerative Diseases · DEIhre-Radiologen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: to test the diagnostic performance of a fully convolutional neural network-based software prototype for clot detection in intracranial arteries using non-enhanced computed tomography (NECT) imaging data. (2) Methods: we retrospectively identified 85 patients with stroke imaging and one intracranial vessel occlusion. An automated clot detection prototype computed clot location, clot length, and clot volume in NECT scans. Clot detection rates were compared to the visual assessment of the hyperdense artery sign by two neuroradiologists. CT angiography (CTA) was used as the ground truth. Additionally, NIHSS, ASPECTS, type of therapy, and TOAST were registered to assess the relationship between clinical parameters, image results, and chosen therapy. (3) Results: the overall detection rate of the software was 66%, while the human readers had lower rates of 46% and 24%, respectively. Clot detection rates of the automated software were best in the proximal middle cerebral artery (MCA) and the intracranial carotid artery (ICA) with 88-92% followed by the more distal MCA and basilar artery with 67-69%. There was a high correlation between greater clot length and interventional thrombectomy and between smaller clot length and rather conservative treatment. (4) Conclusions: the automated clot detection prototype has the potential to detect intracranial arterial thromboembolism in NECT images, particularly in the ICA and MCA. Thus, it could support radiologists in emergency settings to speed up the diagnosis of acute ischemic stroke, especially in settings where CTA is not available.

Indexed as

deep learningintracranial arterial vessel occlusionnon-enhanced brain CT

Identifiers

PMID37761230
PMCPMC10527571
OpenAlexW4386443956

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.