Evidence map›Paper›PMID 37760163›Full record

ArticleBioengineering (Basel, Switzerland)2023

Finite Element Evaluation of the Electric Field Distribution in a Non-Homogeneous Environment.

Elisabetta Sieni, Monica Dettin, Annj Zamuner, Maria Teresa Conconi, Bianca Bazzolo, Cristian Balducci, Paolo Di Barba, Michele Forzan, Patrizia Lamberti, Maria Evelina Mognaschi

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Advanced 3D Cell Culture Technologies and Formats.Bioengineering (Basel, Switzerland) · 2025
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Elisabetta SieniDepartment of Theoretical and Applied Sciences, University of Insubria, Via Dunant 3, 21100 Varese, Italy.ORCID 0000-0001-5297-0576
Monica DettinDepartment of Industrial Engineering, University of Padua, Via Marzolo 9, 35131 Padua, Italy.ORCID 0000-0002-6823-3375
Annj ZamunerDepartment of Civil Environmental and Architectural Engineering, University of Padua, Via Marzolo 9, 35131 Padua, Italy.ORCID 0000-0002-8113-0346
Maria Teresa ConconiDepartment of Pharmaceutical and Pharmacological Sciences, University of Padua, 35131 Padua, Italy.
Bianca BazzoloDepartment of Pharmaceutical and Pharmacological Sciences, University of Padua, 35131 Padua, Italy.
Cristian BalducciDepartment of Industrial Engineering, University of Padua, Via Marzolo 9, 35131 Padua, Italy.ORCID 0009-0002-8285-8512
Paolo Di BarbaDepartment of Electrical, Computer and Biomedical Engineering, Pavia University, Via Ferrata 5, 21100 Pavia, Italy.ORCID 0000-0001-5293-1809
Michele ForzanDepartment of Industrial Engineering, University of Padua, Via Marzolo 9, 35131 Padua, Italy.
Patrizia LambertiItalian Interuniversity Center ICEMB (Interaction between Electromagnetic Fields and Biosystems), DIET University of Genoa, 16145 Genoa, Italy.ORCID 0000-0002-5037-8074
Maria Evelina MognaschiItalian Interuniversity Center ICEMB (Interaction between Electromagnetic Fields and Biosystems), DIET University of Genoa, 16145 Genoa, Italy.ORCID 0000-0003-3300-0296

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Finite element analysis is used in this study to investigate the effect of media inhomogeneity on the electric field distribution in a sample composed of cells and their extracellular matrix. The sample is supposed to be subjected to very high pulsed electric field. Numerically computed electric field distribution and transmembrane potential at the cell membrane in electroporation conditions are considered in order to study cell behavior at different degrees of inhomogeneity. The different inhomogeneity grade is locally obtained using a representative model of fixed volume with cell-cell distance varying in the range of 1-283 um. The conductivity of the extracellular medium was varied between plain collagen and a gel-like myxoid matrix through combinations of the two, i.e., collagen and myxoid. An increase in the transmembrane potential was shown in the case of higher aggregate. The results obtained in this study show the effect of the presence of the cell aggregates and collagen on the transmembrane potential. In particular, by increasing the cell aggregation in the two cases, the transmembrane potential increased. Finally, the simulation results were compared to experimental data obtained by culturing HCC1954 cells in a hyaluronic acid-based scaffold. The experimental validation confirmed the behavior of the transmembrane potential in presence of the collagen: an increase in electroporation at a lower electric field intensity was found for the cells cultured in the scaffolds where there is the formation of collagen areas.

Indexed as

3D scaffoldconductivity inhomogeneityelectroporationfinite element analysis

Identifiers

PMID37760163
PMCPMC10525744

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.