Development and Validation of a Novel In Vitro Joint Testing System for Reproduction of In Vivo Dynamic Muscle Force.

Yangyang Yang, Yufan Wang, Nan Zheng, Rongshan Cheng, Diyang Zou, Jie Zhao, Tsung-Yuan Tsai

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Advanced Engineering Technology in Orthopedic Research.Bioengineering (Basel, Switzerland) · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yangyang YangSchool of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China.
Yufan WangSchool of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China.ORCID 0000-0001-7752-9373
Nan ZhengSchool of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China.
Rongshan ChengSchool of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China.
Diyang ZouSchool of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China.
Jie ZhaoSchool of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China.
Tsung-Yuan TsaiSchool of Biomedical Engineering & Med-X Research Institute, Shanghai Jiao Tong University, Shanghai 200230, China.ORCID 0000-0003-1522-2987

Funding

National Natural Science Foundation of China 31972924Pudong New Area Science & Technology and Development Fund 210H1147900Science and Technology Commission of Shanghai Municipality 22S31906000
6 · The paper itself

Abstract

In vitro biomechanical experiments utilizing cadaveric specimens are one of the most effective methods for rehearsing surgical procedures, testing implants, and guiding postoperative rehabilitation. Applying dynamic physiological muscle force to the specimens is a challenge to reconstructing the environment of bionic mechanics in vivo, which is often ignored in the in vitro experiment. The current work aims to establish a hardware platform and numerical computation methods to reproduce dynamic muscle forces that can be applied to mechanical testing on in vitro specimens. Dynamic muscle loading is simulated through numerical computation, and the inputs of the platform will be derived. Then, the accuracy and robustness of the platform will be evaluated through actual muscle loading tests in vitro. The tests were run on three muscles (gastrocnemius lateralis, the rectus femoris, and the semitendinosus) around the knee joint and the results showed that the platform can accurately reproduce the magnitude of muscle strength (errors range from -6.2% to 1.81%) and changing pattern (goodness-of-fit range coefficient ranges from 0.00 to 0.06) of target muscle forces. The robustness of the platform is mainly manifested in that the platform can still accurately reproduce muscle force after changing the hardware combination. Additionally, the standard deviation of repeated test results is very small (standard ranges of hardware combination 1: 0.34 N~2.79 N vs. hardware combination 2: 0.68 N~2.93 N). Thus, the platform can stably and accurately reproduce muscle forces in vitro, and it has great potential to be applied in the future musculoskeletal loading system.

Indexed as

biomedical devicesdynamic muscle forcesin vitro biomechanical testsnumerical computation methods

Identifiers

PMID37760108