Influence of Implant Macro-Design, -Length, and -Diameter on Primary Implant Stability Depending on Different Bone Qualities Using Standard Drilling Protocols-An In Vitro Analysis.

Milan Stoilov, Ramin Shafaghi, Helmut Stark, Michael Marder, Dominik Kraus, Norbert Enkling

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Milan StoilovDepartment of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany.ORCID 0000-0001-7776-0137
Ramin ShafaghiDepartment of Reconstructive Dentistry and Gerodontology, Bern University, 3012 Bern, Switzerland.
Helmut StarkDepartment of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany.
Michael MarderDepartment of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany.ORCID 0000-0002-1365-7170
Dominik KrausDepartment of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany.
Norbert EnklingDepartment of Prosthodontics, Preclinical Education and Dental Materials Science, Bonn University, 53111 Bonn, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25-50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant's superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes.

Indexed as

bone qualityimmediate loadinginsertion torqueISQprimary stabilityRFA