Irregular Antibody Screening Using a Microdroplet Platform.
Article in Biosensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
- Case Report: A severe drug-induced immune hemolytic anemia caused by vancomycin.Frontiers in medicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The screening procedure for antibodies is considered the most tedious among the three pretransfusion operations, i.e., ABO and Rhesus (Rh) typing, irregular antibody screening/identification, and crossmatching tests. The commonly used screening method for irregular antibodies in clinics at present is a manual polybrene test (MP). The MP test involves numerous reagent replacement and centrifuge procedures, and the sample volume is expected to be relatively less. Herein, screening red blood cells (RBCs) and serum irregular antibodies are encapsulated in microdroplets with a diameter of ~300 μm for a hemagglutination reaction. Owing to the advantage of spatial limitation in microdroplets, screening RBCs and irregular antibodies can be directly agglutinated, thereby eliminating the need for centrifugation and the addition of reagents to promote agglutination, as required by the MP method. Furthermore, the results for a large number of repeated tests can be concurrently obtained, further simplifying the steps of irregular antibody screening and increasing accuracy. Eight irregular antibodies are screened using the proposed platform, and the results are consistent with the MP method. Moreover, the volume of blood samples and antibodies can be reduced to 10 μL and 5 μL, respectively, which is ten times less than that using the MP method.