ArticleMagnetic resonance in medicine2024

Eddy current-induced artifact correction in high b-value ex vivo human brain diffusion MRI with dynamic field monitoring.

Gabriel Ramos-Llordén, Daniel J Park, John E Kirsch, Alina Scholz, Boris Keil, Chiara Maffei, Hong-Hsi Lee, Berkin Bilgic, Brian L Edlow, Choukri Mekkaoui and 3 more

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

13 authors.

Gabriel Ramos-LlordénAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.ORCID 0000-0003-4020-705X
Daniel J ParkAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
John E KirschAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
Alina ScholzInstitute of Medical Physics and Radiation Protection, Mittelhessen University of Applied Sciences, Giessen, Germany.ORCID 0000-0002-3324-6889
Boris KeilInstitute of Medical Physics and Radiation Protection, Mittelhessen University of Applied Sciences, Giessen, Germany.ORCID 0000-0003-0805-8330
Chiara MaffeiAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
Hong-Hsi LeeAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.ORCID 0000-0002-3663-6559
Berkin BilgicAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.ORCID 0000-0002-9080-7865
Brian L EdlowAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
Choukri MekkaouiAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
Anastasia YendikiAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.
Thomas WitzelQ Bio Inc, San Carlos, California, USA.
Susie Y HuangAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, Massachusetts, USA.ORCID 0000-0003-2950-7254

Funding

CONNECTOME 2.0: DEVELOPING THE NEXT GENERATION HUMAN MRI SCANNER FOR BRIDGING STUDIES OF THE MICRO-, MESO- AND MACRO-CONNECTOMEU01EB026996 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI BASSER, PETER J., HUANG, SUSIE YI · 2018 to 2022
$14.2M
Training and Dissemination CoreP41EB030006 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI Bruce Fischl · 2020 to 2026
$10.9M
Data Coordinating CoreU54NS115322 · NINDS · UNIVERSITY OF PENNSYLVANIA · PI SMITH, DOUGLAS HAMILTON · 2019 to 2023
$9.2M
Microstructural Response of the Myocardium to Mechanical LoadR01HL159010 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI MEKKAOUI, CHOUKRI, NGUYEN, CHRISTOPHER T · 2021 to 2024
$3.2M
Toward a Validated in Vivo Imaging Marker of Axonal Damage Predictive of Progressive Disability in Multiple SclerosisR01NS118187 · NINDS · MASSACHUSETTS GENERAL HOSPITAL · PI HUANG, SUSIE YI · 2021 to 2025
$2.8M
Free-Breathing Diffusion Tensor MRI in Patients Following Myocardial InfarctionR01HL131635 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI MEKKAOUI, CHOUKRI · 2016 to 2020
$2.1M
Revealing tissue microstructure in the brain gray matter in Alzheimer's disease using in vivo high-gradient diffusion MRIDP5OD031854 · OD · MASSACHUSETTS GENERAL HOSPITAL · PI LEE, HONG HSI · 2021 to 2025
$2.1M
NHLBI NIH HHS R01 HL131635NHLBI NIH HHS R01 HL159010NIBIB NIH HHS P41 EB030006NIBIB NIH HHS U01 EB026996NIH HHS DP5 OD031854NIH HHS P41-EB030006NIH HHS R01-HL131635NIH HHS R01-HL159010NIH HHS R01-NS118187NIH HHS U01-EB026996NIH HHS U54NS115322NINDS NIH HHS R01 NS118187NINDS NIH HHS U54 NS115322United States Department of Defense W81XWH2210999
6 · The paper itself

Abstract

purposeTo investigate whether spatiotemporal magnetic field monitoring can correct pronounced eddy current-induced artifacts incurred by strong diffusion-sensitizing gradients up to 300 mT/m used in high b-value diffusion-weighted (DW) EPI.

methodsA dynamic field camera equipped with 16

resultsPhase perturbations in the readout induced by residual eddy currents from strong diffusion gradients are highly nonlinear in space and time, vary among diffusion directions, and interfere significantly with the image encoding gradients, changing the k-space trajectory. During the readout, phase modulations between odd and even EPI echoes become non-static and diffusion encoding direction-dependent. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting reduction approaches such as navigator- and structured low-rank-based methods or MUSE followed by image-based distortion correction with the FSL tool "eddy."

conclusionStrong eddy current artifacts characteristic of high-gradient strength DW-EPI can be well corrected with dynamic field monitoring-based image reconstruction.

Indexed as

ArtifactsImage Processing, Computer-AssistedBrainDiffusion Magnetic Resonance ImagingEcho-Planar ImagingHumansImaging, Three-Dimensionaldynamic field monitoringeddyeddy currentsex-vivo diffusion MRIgeometric distortionsghostinghigh-gradient strength diffusion MRI

Identifiers

PMID37753621
PMCPMC10842131

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.