Evidence map›Paper›PMID 37753530›Full record

ArticleFrontiers in surgery2023

Performance evaluation of an AI-based preoperative planning software application for automatic selection of pedicle screws based on computed tomography images.

Shanhang Jia, Yuanzhi Weng, Kai Wang, Huan Qi, Yuhua Yang, Chi Ma, Weijia William Lu, Hao Wu

Abstract read
In one paragraph

Article in Frontiers in surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Review
  2. Article
  3. A comprehensive review of biomechanical factors influencing pedicle screw fixation strength and the critical role of artificial intelligence.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Autonomous Establishment of CT-Independent Sections to Obtain Optimum Pedicle-Screw Axis in Direction, Length, and Safety Margin.The international journal of medical robotics + computer assisted surgery : MRCAS · 2025
    Article
  11. Review
  12. [Orthopedics and trauma surgery in the digital age].Orthopadie (Heidelberg, Germany) · 2024
    Review
  13. Review
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shanhang Jia *Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China.
Yuanzhi Weng *Department of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, Hong Kong SAR, China.
Kai Wang *Department of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China.
Huan QiDepartment of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, Hong Kong SAR, China.
Yuhua YangDepartment of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China.
Chi MaDepartment of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, Hong Kong SAR, China.
Weijia William LuDepartment of Orthopaedics and Traumatology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, Hong Kong SAR, China.
Hao WuDepartment of Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Recent neurosurgical applications based on artificial intelligence (AI) have demonstrated its potential in surgical planning and anatomical measurement. We aimed to evaluate the performance of an AI planning software application on screw length/diameter selection and insertion accuracy in comparison with freehand surgery. Methods: A total of 45 patients with 208 pedicle screw placements on thoracolumbar segments were included in this analysis. The novel AI planning software was developed based on a deep learning model. AI-based pedicle screw placements were selected on the basis of preoperative computed tomography (CT) data, and freehand surgery screw placements were observed based on postoperative CT data. The performance of AI pedicle screw placements was evaluated on the components of screw length, diameter, and Gertzbein grade in comparison with the results achieved by freehand surgery. Results: Among 208 pedicle screw placements, the average screw length/diameters selected by the AI model and used in freehand surgery were 48.65 ± 5.99 mm/7.39 ± 0.42 mm and 44.78 ± 2.99 mm/6.1 ± 0.27 mm, respectively. Among AI screw placements, 85.1% were classified as Gertzbein Grade A (no cortical pedicle breach); among free-hand surgery placements, 64.9% were classified as Gertzbein Grade A. Conclusion: The novel AI planning software application could provide an accessible and safe pedicle screw placement strategy in comparison with traditional freehand pedicle screw placement strategies. The choices of pedicle screw dimensional parameters made by the model, including length and diameter, may provide potential inspiration for real clinical discretion.

Indexed as

AIcomputed tomographyinsertion accuracypedicle screwsurgical planning

Identifiers

PMID37753530
PMCPMC10518392

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.