ArticleEClinicalMedicine2023
Deep learning-based model detects atrial septal defects from electrocardiography: a cross-sectional multicenter hospital-based study.
Article in EClinicalMedicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 25 citations in OpenAlex.
- Clinical importance of heart disease screening in school for detecting atrial septal defects with significant shunt.Heart and vessels · 2026Article
- Comparative evaluation of multimodal large language models for diagnostic accuracy in pediatric electrocardiography: a prospective comparative diagnostic accuracy study.European journal of pediatrics · 2026Article
- Impact of Routine Electrocardiogram Testing in Adult Health Screening on New Outpatient Visit Rates and Cardiovascular Disease Mortality.Circulation reports · 2026Article
- Pediatric Electrocardiogram-Based Deep Learning to Predict Secundum Atrial Septal Defects.Pediatric cardiology · 2025Article
- Review
- Artificial Intelligence in Pediatric Electrocardiography: A Comprehensive Review.Children (Basel, Switzerland) · 2024Review
- Application of artificial intelligence in VSD prenatal diagnosis from fetal heart ultrasound images.BMC pregnancy and childbirth · 2024Article
- A Real-Time End-to-End Framework with a Stacked Model Using Ultrasound Video for Cardiac Septal Defect Decision-Making.Journal of imaging · 2024Article
- Response to the Letter by Matsubara.JMA journal · 2024Article
- Transesophageal echocardiography diagnosis of abnormal left atrium to inferior vena cava communication: A case report.Clinical case reports · 2024Article
- Integration of Artificial Intelligence in Medicines.JMA journal · 2024Article
- Artificial intelligence-enabled 8-lead ECG detection of atrial septal defect among adults: a novel diagnostic tool.Frontiers in cardiovascular medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
18 authors at 3 institutions in 2 countries.
Funding
Abstract
Background: Atrial septal defect (ASD) increases the risk of adverse cardiovascular outcomes. Despite the potential for risk mitigation through minimally invasive percutaneous closure, ASD remains underdiagnosed due to subtle symptoms and examination findings. To bridge this diagnostic gap, we propose a novel screening strategy aimed at early detection and enhanced diagnosis through the implementation of a convolutional neural network (CNN) to identify ASD from 12-lead electrocardiography (ECG). Methods: ECGs were collected from patients with at least one recorded echocardiogram at 3 hospitals from 2 continents (Keio University Hospital from July 2011 to December 2020, Brigham and Women's Hospital from January 2015 to December 2020, and Dokkyo Medical University Saitama Medical Center from January 2010 and December 2021). ECGs from patients with a diagnosis of ASD were labeled as positive cases while the remainder were labeled as negative. ECGs after the closure of ASD were excluded. After randomly splitting the ECGs into 3 datasets (50% derivation, 20% validation, and 30% test) with no patient overlap, a CNN-based model was trained using the derivation datasets from 2 hospitals and was tested on held-out datasets along with an external validation on the 3rd hospital. All eligible ECGs were used for derivation and validation whereas the earliest ECG for each patient was used for the test and external validation. The discrimination of ASD was assessed by the area under the receiver operating characteristic curve (AUROC). Multiple subgroups were examined to identify any heterogeneity. Findings: A total of 671,201 ECGs from 80,947 patients were collected from the 3 institutions. The AUROC for detecting ASD was 0.85-0.90 across the 3 hospitals. The subgroup analysis showed excellent performance across various characteristics Screening simulation using the model greatly increased sensitivity from 80.6% to 93.7% at specificity 33.6% when compared to using overt ECG abnormalities. Interpretation: A CNN-based model using 12-lead ECG successfully identified the presence of ASD with excellent generalizability across institutions from 2 separate continents. Funding: This work was supported by research grants from JST (JPMJPF2101), JSR corporation, Taiju Life Social Welfare Foundation, Kondou Kinen Medical Foundation, Research fund of Mitsukoshi health and welfare foundation, Tokai University School of Medicine Project Research and Internal Medicine Project Research, Secom Science and Technology Foundation, and Grants from AMED (JP23hma922012 and JP23ym0126813). This work was partially supported by One Brave Idea, co-funded by the American Heart Association and Verily with significant support from AstraZeneca and pillar support from Quest Diagnostics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.