Evidence map›Paper›PMID 37753018›Full record

ArticleCureus2023

Convolutional Neural Networks (CNNs) for Pneumonia Classification on Pediatric Chest Radiographs.

Yash S Saboo, Saarthak Kapse, Prateek Prasanna

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yash S SabooRadiology, The University of Texas Health Science Center at San Antonio, San Antonio, USA.
Saarthak KapseBiomedical Informatics, Stony Brook University, Stony Brook, USA.
Prateek PrasannaBiomedical Informatics, Stony Brook University, Stony Brook, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPneumonia is an infectious disease that is especially harmful to those with weak immune systems, such as children under the age of 5. While radiologists' diagnosis of pediatric pneumonia on chest radiographs (CXRs) is often accurate, subtle findings can be missed due to the subjective nature of the diagnosis process. Artificial intelligence (AI) techniques, such as convolutional neural networks (CNNs), can help make the process more objective and precise. However, off-the-shelf CNNs may perform poorly if they are not tuned to their appropriate hyperparameters. Our study aimed to identify the CNNs and their hyperparameter combinations (dropout, batch size, and optimizer) that optimize model performance. METHODOLOGY: Sixty models based on five CNNs (VGG 16, VGG 19, DenseNet 121, DenseNet 169, and InceptionResNet V2) and 12 hyperparameter combinations were tested. Adam, Root Mean Squared Propagation (RmsProp), and Mini-Batch Stochastic Gradient Descent (SGD) optimizers were used. Two batch sizes, 32 and 64, were utilized. A dropout rate of either 0.5 or 0.7 was used in all dropout layers. We used a deidentified CXR dataset of 4200 pneumonia (Figure 1a) and 1600 normal images (Figure 1b). Seventy percent of the CXRs in the dataset were used for training the model, 20% were used for validating the model, and 10% were used for testing the model. All CNNs were trained first on the ImageNet dataset. They were then trained, with frozen weights, on the CXR-containing dataset.  Results: Among the 60 models, VGG-19 (dropout of 0.5, batch size of 32, and Adam optimizer) was the most accurate. This model achieved an accuracy of 87.9%. A dropout of 0.5 consistently gave higher accuracy, area under the receiver operating characteristics curve (AUROC), and area under the precision-recall curve (AUPRC) compared to a dropout of 0.7. The CNNs InceptionResNet V2, DenseNet 169, VGG 16, and VGG 19 significantly outperformed the DenseNet121 CNN in accuracy and AUROC. The Adam and RmsProp optimizer had improved AUROC and AUPRC compared to the SGD optimizer. The batch size had no statistically significant effect on model performance.

conclusionWe recommend using low dropout rates (0.5) and RmsProp or Adam optimizer for pneumonia-detecting CNNs. Additionally, we discourage using the DenseNet121 CNN when other CNNs are available. Finally, the batch size may be set to any value, dependent on computational resources.

Indexed as

artificial intelligence in radiologychest x raycomputer visionconvolutional neural networks (cnn)deep learning artificial intelligencepneumonia detection

Identifiers

PMID37753018
PMCPMC10518240

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.