Evidence map›Paper›PMID 37752342›Full record

ArticleEye (London, England)2024

Factors associated with progressive anisometropia after bilateral intraocular lens implantation in patients with pediatric cataract.

Enze Liu, Lei Lin, Mengdi Zhang, Jiasheng Liu, Mengchao Zhu, Kaiyi Zhu, Er Mo, Jialin Xu, Yun-E Zhao, Jin Li

Open access · greenAbstract read
In one paragraph

Article in Eye (London, England), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 76% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Enze Liu *National Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Lei Lin *National Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Mengdi ZhangNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Jiasheng LiuNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Mengchao ZhuNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Kaiyi ZhuNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Er MoNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Jialin XuNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China.
Yun-E ZhaoNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China. zyehzeye@126.com.ORCID 0000-0003-4401-8053
Jin LiNational Clinical Research Center for Ocular diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, China. lijin_wz@163.com.ORCID 0000-0002-1177-690X
Wenzhou Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo identify factors associated with progressive anisometropia after bilateral intraocular lens (IOL) implantation in patients with pediatric cataract.

methodsClinical and standardized questionnaire data were collected for Sixty-eight patients with pediatric cataract (136 eyes) who underwent bilateral IOL implantation and at least 1 year of follow-up. Univariate and multivariate linear regression models were used to identify factors associated with postoperative anisometropia.

resultsThe median age at IOL implantation was 3.2 years (range: 1-12.4 years), and median follow-up time was 5.7 years (range: 1.1-14 years). At 1 month postoperatively and at the last follow-up, there were 19 (27%) and 31 (46%) cases of anisometropia ≥1 D, 9 (13%) and 15 (22%) cases of anisometropia ≥2 D, and 2 (3%) and 9 (13%) cases of anisometropia ≥3 D, respectively. Compared with 1 month postoperatively, the amount of anisometropia increased in 45 (67%) patients. Greater anisometropia one year or more after bilateral IOL implantation was associated with larger intereye difference in IOL power (P = 0.032, 95%CI 0.013 to 0.285), intereye difference in preoperative axial length (P = 0.018, 95%CI -1.247 to -0.123), presence of strabismus (P = 0.017, 95%CI 0.063-0.601), anisometropia at 1 month postoperatively (P = 0.001, 95%CI 0.126-0.478), and intereye difference in axial length at the last follow-up (P = 0.047, 95%CI 0.005-0.627).

conclusionAnisometropia might progress after bilateral IOL implantation in patients with pediatric cataract. Greater intereye difference in IOL power, presence of strabismus might increase the potential of progressive anisometropia.

Indexed as

AnisometropiaCataractCataract ExtractionLenses, IntraocularStrabismusChildChild, PreschoolFollow-Up StudiesHumansInfantLens Implantation, IntraocularVisual Acuity

Identifiers

PMID37752342
PMCPMC10858177
OpenAlexW4387048088

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.