Evidence map›Paper›PMID 37752177›Full record

ArticleScientific reports2023

Preventing inadvertent drain removal using a novel catheter securement device.

Mario Russo, John Di Capua, April Anlage, Hersh Bendre, Jon Kusner, Graham Lieberman, Sean Jang, Zubin Irani, Ronald S Arellano, Patrick D Sutphin and 6 more

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.8field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. What is the best way to secure a chest drain? A scoping review.Journal of the Intensive Care Society · 2026
    Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 3 institutions in 1 country.

Mario Russo *Harvard Medical School, 25 Shattuck Street, Boston, MA, 02115, USA.
John Di Capua *Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
April AnlageMassachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA, 02139, USA.
Hersh BendreMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Jon KusnerDuke University, 2301 Erwin Rd, Durham, NC, 27710, USA.
Graham LiebermanMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Sean JangDepartment of Radiology, Massachusetts General Hospital, Boston, MA, USA.
Zubin IraniMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Ronald S ArellanoMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Patrick D SutphinMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Sara Smolinski-ZhaoMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Dania DayeMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Sanjeeva P KalvaHarvard Medical School, 25 Shattuck Street, Boston, MA, 02115, USA.
Marc D SucciMassachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA.
Avik Som *Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA. avik.som@mgh.harvard.edu.
Ashraf Thabet *Massachusetts General Hospital, 55 Fruit Street, Boston, MA, 02114, USA. athabet@mgh.harvard.edu.
Massachusetts General Hospital · USHarvard University · USMassachusetts Institute of Technology · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Percutaneous drains have provided a minimally invasive way to treat a wide range of disorders from abscess drainage to enteral feeding solutions to treating hydronephrosis. These drains suffer from a high rate of dislodgement of up to 30% resulting in emergency room visits, repeat hospitalizations, and catheter repositioning/replacement procedures, which incur significant morbidity and mortality. Using ex vivo and in vivo models, a force body diagram was utilized to determine the forces experienced by a drainage catheter during dislodgement events, and the individual components which contribute to drainage catheter securement were empirically collected. Prototypes of a skin level catheter securement and valved quick release system were then developed. The system was inspired by capstans used in boating for increasing friction of a line around a central spool and quick release mechanisms used in electronics such as the Apple MagSafe computer charger. The device was tested in a porcine suprapubic model, which demonstrated the effectiveness of the device to prevent drain dislodgement. The prototype demonstrated that the miniaturized versions of technologies used in boating and electronics industries were able to meet the needs of preventing dislodgement of patient drainage catheters.

Indexed as

CathetersDevice RemovalAnimalsDrainageElectric Power SuppliesElectronicsHumansSwine

Identifiers

PMID37752177
PMCPMC10522644
OpenAlexW4387045534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.