Evidence map›Paper›PMID 37750922›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023

Five or more gender- and size-diverse customizations of distal femur prostheses are needed to improve fit for Chinese knees.

Song Chen, Zhenxin Zheng, Jinku Guo, Shengkun Hong, Weijun Zhou, Jun Xie, Wei Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Song Chen *Department of Orthopedics, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, No.100, Minjiang Avenue, Quzhou, 324000, Zhejiang, China. chensong89@126.com.
Zhenxin Zheng *Department of Orthopedics, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, No.100, Minjiang Avenue, Quzhou, 324000, Zhejiang, China.
Jinku Guo *Department of Orthopedics, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, No.100, Minjiang Avenue, Quzhou, 324000, Zhejiang, China.
Shengkun HongDepartment of Orthopedics, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, No.100, Minjiang Avenue, Quzhou, 324000, Zhejiang, China.
Weijun ZhouDepartment of Orthopedics, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, No.100, Minjiang Avenue, Quzhou, 324000, Zhejiang, China.
Jun XieDepartment of Orthopedics, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, No.100, Minjiang Avenue, Quzhou, 324000, Zhejiang, China. xiejun572572@wmu.edu.cn.
Wei WangDepartment of Orthopedics, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, No.100, Minjiang Avenue, Quzhou, 324000, Zhejiang, China. wwqzhospital@126.com.
Wenzhou Medical University · CNQuzhou City People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeMismatch between partial imported prostheses and Chinese anatomy affects the clinical outcome of the procedure. The purpose of this study was to measure the anatomical dimensions of Chinese distal femurs to provide guidance for the design of more compatible distal femoral prostheses.

methodsA total of 406 healthy distal femurs were reconstructed and measured. Consistency of these measurements and differences in sides, gender, and populations were examined. Parameter correlations were analyzed, and pairs with strong correlations underwent linear regression analysis. The design of distal femoral prostheses was referenced from the results of K-means and hierarchical clustering analysis.

resultsTen parameters were measured, including the trans-epicondylar axis, width of the distal femur (ML), anteroposterior diameter of the distal femur (AP), etc. The intra-class correlation coefficient ranged from 0.795 to 0.999 for intra-observer consistency, and from 0.796 to 0.998 for inter-observer consistency. Males exhibited significantly larger parameters than females, except for the posterior condylar angle (all P values < 0.05). Compared to other populations, substantial differences were observed for most parameters, such as ML, AP, width of lateral femoral condyle, etc. (all P values < 0.05). Clustering analysis suggested that distal femoral prostheses should include at least five sizes to adequately accommodate the sampled population. ML sizes for males were 68, 70, 83, 73, and 89 mm, and for females 64, 65, 71, 67, and 77 mm. AP sizes for males were 56, 60, 60, 64, and 64 mm, and for females 48, 52, 54, 57, and 58 mm.

conclusionsChinese distal femur morphology, as analyzed using 3D techniques, varies significantly between genders and when compared with international data. For improved patient fit, the creation of five or more distal femur prostheses, diversified by gender and size and informed by the associated morphological parameters, is recommended. LEVEL OF EVIDENCE: IV.

Indexed as

FemurTomography, X-Ray ComputedChinaFemaleHumansKneeMaleProstheses and ImplantsDistal femurIntraclass correlation coefficientLinear regressionMeasurementThree-dimensionalUnsupervised machine learning

Identifiers

PMID37750922
OpenAlexW4387032893

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.