Evidence map›Paper›PMID 37749286›Full record

ArticleClinical oral investigations2023

Retrospective clinical study of 1472-unit monolithic zirconia restorations with feather-edge margins realized with digital workflow.

Adolfo Di Fiore, Carlo Monaco, Edoardo Stellini

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical oral investigations, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Mechanical behavior and laboratory survival of thin and ultrathin ceramic crowns: A systematic review and meta-analysis.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
    Pooled it
  2. Trial
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Adolfo Di FioreDepartment of Neuroscience, School of Dentistry, Division of Prosthodontics and Digital Dentistry, University of Padova, Padova, Italy. adolfo.difiore@unipd.it.
Carlo MonacoDepartment of Surgery, Medicine, and Dentistry, University of Modena and Reggio Emilia, Modena, Italy.
Edoardo StelliniDepartment of Neuroscience, School of Dentistry, Division of Prosthodontics and Digital Dentistry, University of Padova, Padova, Italy.
University of Padua · ITUniversity of Modena and Reggio Emilia · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo evaluate the clinical performance of monolithic zirconia restorations with feather-edge margins fabricated by digital impressions. MATERIALS AND

methodsAll participants that present monolithic zirconia restorations with feather-edge margins realized with digital workflow were evaluated during scheduled periodontal maintenance between February and September 2022 according to predetermined inclusion criteria. Clinical performance was assessed using the modified USPHS and periodontal parameters. Overall survival was calculated for monolithic zirconia restorations. Technical and biologic complications were reported. Descriptive statistical analysis and life-table analyses were performed for all data.

resultsA total of 1472 monolithic zirconia FDPs (1279 on abutments and 193 on pontics) placed in 1189 patients (982 males and 490 females) from February 2017 to September 2020 were analyzed. The mean follow-up was 44 months (range 36-61 months), and the overall survival rate was 98.5%. There were 931 single crowns, 96 were 3-unit FDPs, 33 were 4-unit FDPs, 11 were 5-unit FDPs, and 6-unit FDPs. Three single crowns had irreparable cracks, and 6 single crowns and one 4-unit FDP were fractured. One 3-unit FDP failed due to tooth fracture and 5 single crowns failed due to endodontic failure. The loss of retention was noted in 25 monolithic zirconia FDPs and hypersensitivity in 44 single crowns. Biologic complications were uncommon.

conclusionsBased on the results and its limitations, the monolithic zirconia FPDs and digital impressions represent a favorable prosthetic treatment similar to that reported with other margin designs CLINICAL RELEVANCE: Monolithic zirconia restorations on vertical-margin abutments fabricated using a digital workflow demonstrate excellent clinical performance. The digital clinical workflow without the use of a cast means a reduction in costs, steps, and operating time.

Indexed as

Biological ProductsCrownsComputer-Aided DesignDental Restoration FailureFemaleHumansMaleRetrospective StudiesWorkflowZirconiumBiological ProductsZirconiumzirconium oxideAbutment toothDigital impressionDigital workflowVertical marginZirconia

Identifiers

PMID37749286
OpenAlexW4387033205

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.