Evidence map›Paper›PMID 37748801›Full record

ArticleRegional anesthesia and pain medicine2024

Water-circulating probes significantly modify lesion length and axon damage in cooled radiofrequency ablations when compared with similar-sized standard radiofrequency probes in rats.

Alyssa Cobbs, Guillermo Alas, Ruchi Yadav, Jacques Mayeux, Maxim S Eckmann, David Anthony Provenzano, Arthur W English, Alencia Washington, Ruoya Wang

Abstract readComparative Study
In one paragraph

Article in Regional anesthesia and pain medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Alyssa CobbsResearch and Development, Avanos Medical Inc, Alpharetta, Georgia, USA alyssa.cobbs@avanos.com.ORCID 0009-0003-1060-3577
Guillermo AlasResearch and Development, Avanos Medical Inc, Alpharetta, Georgia, USA.
Ruchi YadavResearch and Development, Avanos Medical Inc, Alpharetta, Georgia, USA.
Jacques MayeuxResearch and Development, Avanos Medical Inc, Alpharetta, Georgia, USA.
Maxim S EckmannAnesthesiology, Univ Texas Hlth Sci Ctr San Antonio, San Antonio, Texas, USA.
David Anthony ProvenzanoPain Diagnostics and Interventional Care, Sewickley, Pennsylvania, USA.ORCID 0000-0002-2147-3523
Arthur W EnglishCell Biology, Emory University, Atlanta, Georgia, USA.
Alencia WashingtonResearch and Development, Avanos Medical Inc, Alpharetta, Georgia, USA.
Ruoya WangResearch and Development, Avanos Medical Inc, Alpharetta, Georgia, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionPreclinical research demonstrated water-cooled radiofrequency (CRF) ablations have a significant impact on structural and functional changes compared to standard radiofrequency (SRF) ablations. Clinical procedures utilizing RF to treat chronic pain conditions also show sustained functional outcomes. We hypothesize that the design of the RF probes plays an important role in interventional procedure success, but it remains unclear which specific design features.

methodsRF ablations were performed in male Lewis rats (n=51) using multiple-sized probes for CRF (17 Ga/2 mm and 17Ga/4 mm) and SRF (22Ga/5 mm, 18Ga/10 mm and 16Ga/10 mm) to evaluate generator energy output, lesion length, axon damage by histology and nerve function analysis via electromyography. To exclude probe design variables beyond size and remain objective, we tested cooled probes with and without water circulation, which resulted in the CRF probe performing like an SRF probe.

resultsConsistent with our previous findings in smaller probes, CRF large probes delivered more energy (p<0.01) and generated multiple zones of thermal damage in sciatic nerves. When the water-circulating feature was turned off, however, energy output (p<0.001) and lesion length (p<0.05) was significantly reduced. CRF probes with the water circulation also featured significantly more axonal disruption, than larger sized SRF probes (p<0.0001).

conclusionsOverall, this data confirms that CRF's water-circulating technology has a greater impact on energy deposition, lesion length and axon damage compared with SRF ablations. Moreover, results suggest that the structural differences between RF modalities cannot be solely attributed to probe size, and it may shed light on its differences in clinical outcomes.

Indexed as

AxonsRats, Inbred LewSciatic NerveWaterAnimalsCatheter AblationCold TemperatureEquipment DesignMaleRadiofrequency AblationRatsWaterAnimal ExperimentationCHRONIC PAINPain ManagementPeripheral Nerve Injuries

Identifiers

PMID37748801
PMCPMC11187385

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.