ArticleIEEE transactions on biomedical circuits and systems2024
An MRI Compatible Data Acquisition Device for Rat Brain Recording Inside 16.4T Magnet.
Article in IEEE transactions on biomedical circuits and systems, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Concurrent recording of neural activities and functional magnetic resonance imaging (fMRI) data is useful for studying the neurovascular coupling relationship. This article presents a low-noise, frequency-shaping based neural recorder chip that is insensitive to radio frequency (RF) pulses and gradient echo artifacts under strong magnetic environment. To support simultaneous recording of local field potentials (LFPs), extracellular spikes, and fMRI data, a magnetic resonance imaging (MRI) compatible data acquisition (DAQ) device based on the designed recorder chip is developed with multiple circuit optimization techniques. Bench-top measurement shows that the designed DAQ device has 4.5 μV input-referred noise integrated from 300 Hz to 3000 Hz, which is not greatly affected by electromagnetic interference (EMI) at ultrahigh magnetic field (UMF, 16.4 T). In animal experiments, the designed DAQ device has been demonstrated to be capable of acquiring both the LFPs and extracellular spikes from a rat's brain before, during, and after MRI scanning. Besides, no obvious artifacts are seen from the designed DAQ device at multiple typical MRI scanning modes, and the system recovery time after gradient artifacts is reduced from more than 25 ms to less than 5 ms. The proposed DAQ device architecture based on the frequency-shaping neural recorder chip is MRI compatible and can provide highly competitive performance for concurrent recording of neural activities and fMRI data.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.