Evidence map›Paper›PMID 37747860›Full record

ArticleIEEE transactions on biomedical circuits and systems2024

An MRI Compatible Data Acquisition Device for Rat Brain Recording Inside 16.4T Magnet.

Jian Xu, Anh Tuan Nguyen, Wenfeng Zhao, Wei Chen, Zhi Yang

Abstract read
In one paragraph

Article in IEEE transactions on biomedical circuits and systems, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jian Xu
Anh Tuan Nguyen
Wenfeng Zhao
Wei Chen
Zhi Yang

Funding

Integrated fMRI Methods to Study Neurophysiology and Circuit Dynamics at Laminar and Columnar LevelR01MH111413 · NIMH · UNIVERSITY OF MINNESOTA · PI CHEN, WEI · 2016 to 2020
$4.4M
NIMH NIH HHS R01 MH111413
6 · The paper itself

Abstract

Concurrent recording of neural activities and functional magnetic resonance imaging (fMRI) data is useful for studying the neurovascular coupling relationship. This article presents a low-noise, frequency-shaping based neural recorder chip that is insensitive to radio frequency (RF) pulses and gradient echo artifacts under strong magnetic environment. To support simultaneous recording of local field potentials (LFPs), extracellular spikes, and fMRI data, a magnetic resonance imaging (MRI) compatible data acquisition (DAQ) device based on the designed recorder chip is developed with multiple circuit optimization techniques. Bench-top measurement shows that the designed DAQ device has 4.5 μV input-referred noise integrated from 300 Hz to 3000 Hz, which is not greatly affected by electromagnetic interference (EMI) at ultrahigh magnetic field (UMF, 16.4 T). In animal experiments, the designed DAQ device has been demonstrated to be capable of acquiring both the LFPs and extracellular spikes from a rat's brain before, during, and after MRI scanning. Besides, no obvious artifacts are seen from the designed DAQ device at multiple typical MRI scanning modes, and the system recovery time after gradient artifacts is reduced from more than 25 ms to less than 5 ms. The proposed DAQ device architecture based on the frequency-shaping neural recorder chip is MRI compatible and can provide highly competitive performance for concurrent recording of neural activities and fMRI data.

Indexed as

BenzoquinonesMagnetic FieldsMagnetsAnimalsArtifactsBrainMagnetic Resonance ImagingRatsBenzoquinonesDAQ

Identifiers

PMID37747860
PMCPMC11132088

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.