Evidence map›Paper›PMID 37744441›Full record

ReviewFrontiers in pediatrics2023

Accuracy of lung and diaphragm ultrasound in predicting infant weaning outcomes: a systematic review and meta-analysis.

Yang Gao, Hong Yin, Mei-Huan Wang, Yue-Hua Gao

Registry-linked trialAbstract readReview
In one paragraph

Review in Frontiers in pediatrics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07240038 (Evaluation of an Evidence Based, Bundled Intervention to Reduce Incidence of Ventilator-associated Pneumonia in Neonatal Units), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07240038 recruitingnot on this mapstarted 2024, after this paper: background citation

Evaluation of an Evidence Based, Bundled Intervention to Reduce Incidence of Ventilator-associated Pneumonia in Neonatal Units (INBERNAV-Neo)

Typeobservational_patient_registrySponsorBiobizkaia Health Research InstituteRan2024 to 2026Enrolled1,500ConditionsPneumonia Ventilator Associated, Pneumonia Neonatal, Healthcare-associated InfectionsArmsMultimodal intervention to reduce the incidence of ventilator-associated pneumonia by training the health care team in specific and general evidence-based good clinical practices., Technique with a blind-protected catheter
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Observational
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yang GaoDepartment of Ultrasound, Shandong Provincial Maternal and Child Health Care Hospital, Jinan, China.
Hong YinDepartment of Ultrasound, Shandong Provincial Maternal and Child Health Care Hospital, Jinan, China.
Mei-Huan WangDepartment of Ultrasound, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.
Yue-Hua GaoDepartment of Ultrasound, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Although lung and diaphragm ultrasound are valuable tools for predicting weaning results in adults with MV, their relevance in children is debatable. The goal of this meta-analysis was to determine the predictive value of lung and diaphragm ultrasound in newborn weaning outcomes. Methods: For eligible studies, the databases MEDLINE, Web of Science, Cochrane Library, PubMed, and Embase were thoroughly searched. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) method was used to evaluate the study's quality. Results were gathered for sensitivity, specificity, diagnostic odds ratio (DOR), and the area under the curve of summary receiver operating characteristic curves (AUSROC). To investigate the causes of heterogeneity, subgroup analyses and meta-regression were conducted. Results: A total of 11 studies were suitable for inclusion in the meta-analysis, which included 828 patients. The pooled sensitivity and specificity of lung ultrasound (LUS) were 0.88 (95%CI, 0.85-0.90) and 0.81 (95%CI, 0.75-0.87), respectively. The DOR for diaphragmatic excursion (DE) is 13.17 (95%CI, 5.65-30.71). The AUSROC for diaphragm thickening fraction (DTF) is 0.86 (95%CI, 0.82-0.89). The most sensitive and specific method is LUS. The DE and DTF were the key areas where study heterogeneity was evident. Conclusions: Lung ultrasonography is an extremely accurate method for predicting weaning results in MV infants. DTF outperforms DE in terms of diaphragm ultrasound predictive power.

Indexed as

diaphragm ultrasoundendotracheal extubationlung ultrasoundmechanical ventilationpediatric critical careweaning

Identifiers

PMID37744441
PMCPMC10511769

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials