Evidence map›Paper›PMID 37743436›Full record

ArticleJournal of ultrasound2023

Reliability of a special device for measuring the cross-sectional area of the patellar tendon by ultrasonography.

Morgana Lunardi, Franklin Everaldo Furtado, Raphael Luiz Sakugawa, Francesca Chaida Sonda, Lucas Tavares Sampaio, Fernando Diefenthaeler

Abstract read
In one paragraph

Article in Journal of ultrasound, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Morgana LunardiLaboratório de Biomecânica, Centro de Desportos, Universidade Federal de Santa Catarina, Campus Universitário, Trindade, Florianópolis, SC, 88040-900, Brazil.ORCID https://orcid.org/0000-0002-7756-2517
Franklin Everaldo FurtadoLaboratório de Biomecânica, Centro de Desportos, Universidade Federal de Santa Catarina, Campus Universitário, Trindade, Florianópolis, SC, 88040-900, Brazil.ORCID https://orcid.org/0009-0007-6207-1532
Raphael Luiz SakugawaLaboratório de Biomecânica, Centro de Desportos, Universidade Federal de Santa Catarina, Campus Universitário, Trindade, Florianópolis, SC, 88040-900, Brazil.ORCID https://orcid.org/0000-0002-4162-232X
Francesca Chaida SondaLaboratório de Pesquisa do Exercício, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brazil.ORCID https://orcid.org/0000-0002-5762-7918
Lucas Tavares SampaioLaboratório de Biomecânica, Centro de Desportos, Universidade Federal de Santa Catarina, Campus Universitário, Trindade, Florianópolis, SC, 88040-900, Brazil.ORCID https://orcid.org/0000-0003-2049-1700
Fernando DiefenthaelerLaboratório de Biomecânica, Centro de Desportos, Universidade Federal de Santa Catarina, Campus Universitário, Trindade, Florianópolis, SC, 88040-900, Brazil. fernando.diefenthaeler@ufsc.br.ORCID http://orcid.org/0000-0001-5632-8994

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this study was to evaluate the intra- and inter-rater reliability and agreement between conditions with and without a special device (SD) in the evaluation of the patellar tendon (PT) cross-sectional area (CSA). Forty trained adult volunteers participated in the study. With the knee positioned at 90°, the ultrasound probe was placed in the transverse plane at 25, 50, and 75% of the PT length. Two raters and one analyzer obtained the images. We use a two-way ANOVA with a significance level of α = 0.05. No significant differences were found between raters or conditions. Intra-rater reliability ranged from moderate to good. Inter-rater reliability without the SD ranged from low to good, improving from moderate to good when the SD was used. Evaluation of the PT ends showed a lower coefficient of variation with the SD. We observed a moderate correlation at the ends and a strong correlation in the middle between conditions. The mean difference in the three positions is small (~ 0.013 cm

Indexed as

Patellar LigamentAdultHumansKnee JointObserver VariationReproducibility of ResultsUltrasonographyInter-raterIntra-raterKneeReproducibilityTendonTendon morphology

Identifiers

PMID37743436
PMCPMC10632332

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.