Evidence map›Paper›PMID 37742007›Full record

ArticleBMC musculoskeletal disorders2023

Radiation exposure for pedicle screw placement with three different navigation system and imaging combinations in a sawbone model.

Nils Beisemann, Jula Gierse, Eric Mandelka, Frank Hassel, Paul A Grützner, Jochen Franke, Sven Y Vetter

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nils BeisemannResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), BG Klinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Jula GierseResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), BG Klinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Eric MandelkaResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), BG Klinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Frank HasselDepartment of Spine Surgery, Loretto Hospital, Mercystrasse 6, 79100, Freiburg Im Breisgau, Germany.
Paul A GrütznerResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), BG Klinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Jochen FrankeResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), BG Klinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany.
Sven Y VetterResearch Group Medical Imaging and Navigation in Trauma and Orthopedic Surgery (MINTOS), BG Klinik (BG Trauma Center) Ludwigshafen, Ludwig-Guttmann-Strasse 13, 67071, Ludwigshafen, Germany. sven.vetter@bgu-ludwigshafen.de.ORCID http://orcid.org/0000-0001-8024-9276

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStudies have shown that pedicle screw placement using navigation can potentially reduce radiation exposure of surgical personnel compared to conventional methods. Spinal navigation is based on an interaction of a navigation software and 3D imaging. The 3D image data can be acquired using different imaging modalities such as iCT and CBCT. These imaging modalities vary regarding acquisition technique and field of view. The current literature varies greatly in study design, in form of dose registration, as well as navigation systems and imaging modalities analyzed. Therefore, the aim of this study was a standardized comparison of three navigation and imaging system combinations in an experimental setting in an artificial spine model.

methodsIn this experimental study dorsal instrumentation of the thoracolumbar spine was performed using three imaging/navigation system combinations. The system combinations applied were the iCT/Curve, cCBCT/Pulse and oCBCT/StealthStation. Referencing scans were obtained with each imaging modality and served as basis for the respective navigation system. In each group 10 artificial spine models received bilateral dorsal instrumentation from T11-S1. 2 referencing and control scans were acquired with the CBCTs, since their field of view could only depict up to five vertebrae in one scan. The field of view of the iCT enabled the depiction of T11-S1 in one scan. After instrumentation the region of interest was scanned again for evaluation of the screw position, therefore only one referencing and one control scan were obtained. Two dose meters were installed in a spine bed ventral of L1 and S1. The dose measurements in each location and in total were analyzed for each system combination. Time demand regarding screw placement was also assessed for all system combinations.

resultsThe mean radiation dose in the iCT group measured 1,6 ± 1,1 mGy. In the cCBCT group the mean was 3,6 ± 0,3 mGy and in the oCBCT group 10,3 ± 5,7 mGy were measured. The analysis of variance (ANOVA) showed a significant (p < 0.0001) difference between the three groups. The multiple comparisions by the Kruskall-Wallis test showed no significant difference for the comparison of iCT and cCBCT (p

conclusionUnder standardized conditions oCBCT navigation demanded twice as much radiation as the cCBCT for the same number of scans, while the radiation exposure measured for the iCT and cCBCT for one scan was comparable. Yet, time effort was significantly less for oCBCT based navigation. However, for transferability into clinical practice additional studies should follow evaluating parameters regarding feasibility and clinical outcome under standardized conditions.

Indexed as

Pedicle ScrewsRadiation ExposureAnalysis of VarianceDiagnostic ImagingHeart RateHumans3D imagingDorsal instrumentationRadiation exposureSpinal navigation

Identifiers

PMID37742007
PMCPMC10517448

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.