ArticleScientific reports2023
Continuous aerosol monitoring and comparison of aerosol exposure based on smoke dispersion distance and concentrations during oxygenation therapy.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
- Erratum issued
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study evaluated the aerosol exposure risks while using common noninvasive oxygenation devices. A simulated mannequin was designed to breathe at a minute ventilation of 20 L/min and used the following oxygen-therapy devices: nasal cannula oxygenation (NCO) at 4 and 15 L/min, nonrebreathing mask (NRM) at 15 L/min, simple mask at 6 L/min, combination of NCO at 15 L/min and NRM at 15 L/min, high-flow nasal cannula (HFNC) at 50 L/min, and flush rate NRM. Two-dimension of the dispersion distance and the aerosol concentrations were measured at head, trunk, and foot around the mannequin for over 10 min. HFNC and flush-rate NRM yielded the longest dispersion distance and highest aerosol concentrations over the three sites of the mannequin than the other oxygenation devices and should use with caution. For flow rates of < 15 L/min, oxygenation devices with mask-like effects, such as NRM or NCO with NRM, decreased aerosol dispersion more effectively than NCO alone or a simple mask. In the upright position, the foot area exhibited the highest aerosol concentration regardless of the oxygenation device than the head-trunk areas of the mannequin. Healthcare workers should be alert even at the foot side of the patient while administering oxygenation therapy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials