Evidence map›Paper›PMID 37740733›Full record

Observational studyJournal of anesthesia2024

Continuous cardiac output estimation using a new modified Fick method during off-pump coronary artery bypass graft surgery: a retrospective observational study.

Chahyun Oh, Hyung-Chul Lee, Soomin Lee, Man-Shik Shim, Soo Bin Yoon, Jinsik Jung, Seok-Hwa Yoon, Yoon-Hee Kim, Youngkwon Ko, Boohwi Hong and 1 more

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Journal of anesthesia, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Chahyun Oh *Department of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Hyung-Chul Lee *Department of Anesthesiology and Pain Medicine Seoul National University College of Medicine, Seoul National University Hospital, Seoul, Korea.
Soomin LeeDepartment of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Man-Shik ShimDepartment of Thoracic & Cardiovascular Surgery, Chungnam National University Hospital, Daejeon, Korea.
Soo Bin YoonDepartment of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul, Korea.
Jinsik JungDepartment of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Seok-Hwa YoonDepartment of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Yoon-Hee KimDepartment of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Youngkwon KoDepartment of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Boohwi HongDepartment of Anesthesiology and Pain Medicine, Chungnam National University Hospital, Daejeon, Korea.
Yunseo KuDepartment of Biomedical Engineering, Chungnam National University College of Medicine, 266 Munhwa-Ro(St), Jung-Gu, Daejeon, 35015, Korea. yunseo.ku@cnu.ac.kr.ORCID 0000-0003-2737-4427

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSeveral technical aspects of the Fick method limit its use intraoperatively. A data-driven modification of the Fick method may enable its use in intraoperative settings.

methodsThis two-center retrospective observational study included 57 (28 and 29 in each center) patients who underwent off-pump coronary artery bypass graft (OPCAB) surgery. Intraoperative recordings of physiological data were obtained and divided into training and test datasets. The Fick equation was used to calculate cardiac output (CO-Fick) using ventilator-determined variables, intraoperative hemoglobin level, and SvO

resultsIncreased deviation between CO-Fick and CCO was observed when oxygen extraction was low. The root mean square error of CO-Fick was decreased from 6.07 L/min to 0.70 L/min after the modification. CO-Fick-AD showed a mean bias of 0.17 (95% CI 0.00-0.34) L/min, with a 36.4% (95% CI 30.6-44.4%) error. The concordance rates of CO-Fick-AD ranged from 73.3 to 87.1% depending on the time interval and exclusion zone.

conclusionsThe original Fick method is not reliable when oxygen extraction is low, but a modification using data-driven approach could enable continuous estimation of cardiac output during the dynamic intraoperative period with minimal bias. However, further improvements in precision and trending ability are needed.

Indexed as

Coronary Artery Bypass, Off-PumpCardiac OutputHumansMonitoring, PhysiologicOxygenOxygen ConsumptionThermodilutionOxygenCardiac outputCoronary artery bypassHemodynamic monitoringIntraoperative monitoringOxygen consumptionOxygen saturation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.