Evidence map›Paper›PMID 37740640›Full record

ArticleJournal of medical radiation sciences2024

Improvement in male pelvis magnetic resonance image contouring following radiologist-delivered training.

Bronwyn Oar, Amy Brown, Glen Newman, Alan Boles, Christopher N Rumley, Rachel Doyle, John Baines, Alex Tan

Open access · goldAbstract read
In one paragraph

Article in Journal of medical radiation sciences, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Bronwyn OarTownsville University Hospital, Townsville, Queensland, Australia.ORCID https://orcid.org/0000-0003-3739-2223
Amy BrownTownsville University Hospital, Townsville, Queensland, Australia.ORCID https://orcid.org/0000-0003-4520-2485
Glen NewmanTownsville University Hospital, Townsville, Queensland, Australia.ORCID https://orcid.org/0000-0002-8481-3935
Alan BolesQueensland XRay, Townsville, Queensland, Australia.
Christopher N RumleyTownsville University Hospital, Townsville, Queensland, Australia.ORCID https://orcid.org/0000-0002-2703-2374
Rachel DoyleTownsville University Hospital, Townsville, Queensland, Australia.
John BainesTownsville University Hospital, Townsville, Queensland, Australia.
Alex TanTownsville University Hospital, Townsville, Queensland, Australia.ORCID https://orcid.org/0000-0003-2902-4025
Townsville Hospital · AUQueensland University of Technology · AU

Funding

Townsville Hospital and Health Service SERTA 2019_04
6 · The paper itself

Abstract

introductionThe magnetic resonance linear accelerator (MRL) combines both magnetic resonance imaging and a linear accelerator, allowing for daily treatment adaptation. This study aimed to assess the impact of radiologist-delivered training in magnetic resonance (MR) contouring of relevant structures within the male pelvis.

methodsTwo radiation oncologists, two radiation oncology registrars and seven radiation therapists completed contouring on 10 male pelvis MR datasets both pre- and post-training. A 2-hour MR anatomy training session was delivered by a radiologist, who also provided the 'gold standard' contours. The pre- and post-training contours were compared against the gold standard with Dice similarity coefficient (DSC) and Hausdorff distances calculated; and the pre- and post-confidence scores and timing were compared.

resultsThe improvement in DSC were significant in prostate, rectum and seminal vesicles, with a post-training median DSC of 0.87 ± 0.06, 0.92 ± 0.04 and 0.80 ± 0.14, respectively. The median Hausdorff improved with a median of 1.46 ± 0.78 mm, 0.52 ± 0.32 mm and 1.11 ± 0.86 mm for prostate, rectum and seminal vesicles, respectively. Bladder concordance was high both pre- and post-training. Urethra contours improved post-training, however, remained difficult to contour with a median post-DSC of 0.51 ± 0.24. Overall, confidence scoring improved (P < 0.001) and timing decreased by an average of 4.4 ± 16.4 min post-training.

conclusionRadiologist-delivered training improved concordance of male pelvis contouring on MR datasets. Further work is required in the identification of urethra on MRs. These findings are of importance in the MRL adaptive workflow.

Indexed as

Prostatic NeoplasmsHumansMagnetic Resonance ImagingMalePelvisRadiation OncologistsRadiotherapy Planning, Computer-Assistedmagnetic resonance imagingmagnetic resonance linear acceleratorplanningradiation oncology

Identifiers

PMID37740640
PMCPMC10920942
OpenAlexW4386979736

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.