Evidence map›Paper›PMID 37739221›Full record

Trial reportIndian heart journal

The COBRA II (COmplex Bifurcation lesions: RAndomized comparison of a fully bioresorbable modified-T stenting strategy versus bifurcation reconstruction with a dedicated self-expanding stent in combination with bioresorbable scaffolds) study: Final 5-year follow-up.

Johan Bennett, Walter Desmet, Christophe Dubois

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Indian heart journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Johan BennettDepartment of Cardiovascular Medicine, University Hospitals Leuven, Leuven, Belgium; Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium. Electronic address: johan.bennett@uzleuven.be.
Walter DesmetDepartment of Cardiovascular Medicine, University Hospitals Leuven, Leuven, Belgium; Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium.
Christophe DuboisDepartment of Cardiovascular Medicine, University Hospitals Leuven, Leuven, Belgium; Department of Cardiovascular Sciences, Katholieke Universiteit Leuven, Leuven, Belgium.
KU Leuven · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn order to advocate further research in bioresorbable scaffold (BVS) technology we report the final 5-year outcomes of the COBRA II study, the only randomized controlled trial (RCT) performed to investigate the safety, feasibility, and performance of Absorb BVS (Abbott Vascular) in true coronary bifurcations.

methodsCOBRA II was a prospective single-center RCT. Fifteen patients with true coronary bifurcation lesions were randomized to bifurcation treatment with self-expanding biolimus-eluting Axxess bifurcation device (Biosensors International) combined with additional bioresorbable everolimus-eluting Absorb BVS in the bifurcation branches on (Axxess group) or to 2-stent mod-T stenting technique with Absorb BVS (mod-T group). Optical coherence tomography was performed post-procedure and at 30-months. The primary endpoint was change in minimal luminal area (MLA) on OCT from baseline to 30-months.

resultsFifteen patients with coronary bifurcation lesions were randomized to the Axxess group (n = 8) or Modified-T group (n = 7). At 30 months, MLAs were significantly smaller than post-procedure in the majority of bifurcation segments treated with BVS due to neointima formation, while MLAs in the proximal Axxess segment remained stable (primary endpoint). Five-year clinical follow-up was available for all patients. Only 1 major adverse cardiac event occurred; a patient underwent target lesion revascularization at 30 months in the Axxess group. There were no cases of cardiac death, spontaneous MI, or stent/scaffold thrombosis.

conclusionsIn this small RCT bifurcation study, BVS luminal dimensions were significantly smaller at 30 months, with acute strut discontinuities and late Intraluminal dismantling frequently observed, although acceptable clinical outcomes were noted at 5 years.

Indexed as

Coronary Artery DiseaseDrug-Eluting StentsAbsorbable ImplantsFollow-Up StudiesHumansProsthesis DesignSirolimusStentsTreatment OutcomeSirolimusBioresorbable scaffoldClinical outcomeCoronary bifurcationDedicated devices

Identifiers

PMID37739221
PMCPMC10774576
OpenAlexW4386898567

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.