SynthesisEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2023
Comparisons of effectiveness and safety between on-label dosing, off-label underdosing, and off-label overdosing in Asian and non-Asian atrial fibrillation patients treated with rivaroxaban: a systematic review and meta-analysis of observational studies.
Synthesis in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 3 syntheses or guidelines pooled it, 18 citations in OpenAlex.
- Clinical outcomes of off-label DOAC underdosing in Japanese patients with atrial fibrillation: a systematic review and meta-analysis.Journal of thrombosis and thrombolysis · 2025Pooled it
- Adherence and persistence with direct oral anticoagulants by dose regimen: A systematic review.British journal of clinical pharmacology · 2025Pooled it
- Pooled it
- Bleeding risk of rivaroxaban and edoxaban with and without amiodarone in atrial fibrillation patients: a prospective cohort study.European journal of clinical pharmacology · 2026Article
- Edoxaban for stroke prevention in Chinese patients with atrial fibrillation: 1-year follow-up of the ETNA-AF-China study.Frontiers in pharmacology · 2026Article
- Apixaban outcomes in atrial fibrillation patients with a single-dose reduction criterion: ASPIRE 1-year results.European heart journal. Cardiovascular pharmacotherapy · 2025Observational
- Number needed to treat for net clinical benefit of oral anticoagulants in Asian patients with atrial fibrillation.Journal of arrhythmia · 2025Article
- Outcomes of 10 mg Rivaroxaban in Nonvalvular Atrial Fibrillation Patients With CrCl ≥ 50 mL/min: A Retrospective Cohort Study.Cardiovascular therapeutics · 2025Article
- Impact of different doses of rivaroxaban on clinical outcomes in elderly patients with non-valvular atrial fibrillation: a real-world study.Frontiers in pharmacology · 2025Article
- The global burden of atrial fibrillation: Voices from Asia and Brazil.Heart rhythm O2 · 2024Article
- Patient Outcomes in Very Elderly Patients With Non-Valvular Atrial Fibrillation - ANAFIE Registry.Circulation reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsLimited real-world data show that rivaroxaban following dosage criteria from either ROCKET AF [20 mg/day or 15 mg/day if creatinine clearance (CrCl) < 50 mL/min] or J-ROCKET AF (15 mg/day or 10 mg/day if CrCl < 50 mL/min) is associated with comparable risks of thromboembolism and bleeding with each other in patients with non-valvular atrial fibrillation (NVAF). We are aimed to study whether these observations differ between Asian and non-Asian subjects. METHODS AND
resultsA systematic review and meta-analysis with random effects was conducted to estimate the aggregate hazard ratio (HR) and 95% confidence interval (CI) using PubMed and MEDLINE databases from 8 September 2011 to 31 December 2022 searched for adjusted observational studies that reported relevant clinical outcomes of NVAF patients receiving rivaroxaban 10 mg/day if CrCl > 50 mL/min, on-label dose rivaroxaban eligible for ROCKET AF or J-ROCKET AF, and rivaroxaban 20 mg/day if CrCl < 50 mL/min. Effectiveness and safety endpoints were compared between ROCKET AF and J-ROCKET AF dosing regimen in Asian and non-Asian subjects, separately. Also, risks of events of rivaroxaban 10 mg/day despite of CrCl > 50 mL/min and rivaroxaban 20 mg/day despite of CrCl < 50 mL/min were compared to that of 'ROCKET AF/J-ROCKET AF dosing'. Sensitivity analyses were performed by sequential elimination of each study from the pool. The meta-regression analysis was performed to explore the influence of potential factors on the effectiveness and safety outcomes. Eighteen studies involving 67 571 Asian and 54 882 non-Asian patients were included. Rivaroxaban following J-ROCKET AF criteria was associated with comparable risks of thromboembolism in the Asian subgroup, whereas rivaroxaban following J-ROCKET AF criteria was associated with higher risks of all-cause mortality (HR:1.30; 95% CI:1.05-1.60) compared with that of ROCKET AF criteria in the non-Asian population. There were no differences in risks of major bleeding between rivaroxaban following J-ROCKET AF vs. ROCKET AF criteria either in the Asian or non-Asian population. The use of rivaroxaban 10 mg despite of CrCl > 50 mL/min was associated with a higher risk of thromboembolism (HR:1.64; 95% CI:1.28-2.11) but lower risk of major bleeding (HR:0.72; 95% CI:0.57-0.90) compared with eligible dosage criteria. The use of rivaroxaban 20 mg despite of CrCl < 50 mL/min was associated with worse clinical outcomes in the risks of thromboembolism (HR:1.32; 95% CI:1.09-1.59), mortality (HR:1.33; 95% CI:1.10-1.59), and major bleeding (HR:1.26; 95% CI:1.03-1.53) compared with eligible dosage criteria. The pooled results were generally in line with the primary effectiveness and safety outcomes by removing a single study at one time. Meta-regression analyses failed to detect the bias in most potential patient characteristics associated with the clinical outcomes.
conclusionRivaroxaban dosing regimen following J-ROCKET criteria may serve as an alternative to ROCKET AF criteria for the Asian population with NVAF, whereas the dosing regimen following ROCKET AF criteria was more favourable for the non-Asian population. The use of rivaroxaban 10 mg despite of CrCl > 50 mL/min was associated with a higher risk of thromboembolism but a lower risk of major bleeding, while use of rivaroxaban 20 mg despite of CrCl < 50 mL/min was associated with worse outcome in most clinical events.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.