Evidence map›Paper›PMID 37737167›Full record

ArticleBMC musculoskeletal disorders2023

Subtrochanteric fracture after femoral neck system of femoral neck fractures: a report of four cases.

John C Fisher, Christopher Gerzina, Kaitlin Rush, Cyrus Caroom

Open access · goldAbstract readCase Reports
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
5.1field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Fatigue testing of a self-compression screw model in Pauwels III fracture: an in vitro analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

John C FisherTexas Tech University Health Sciences Center (TTUHSC), 3601 4th St., Lubbock, Tx, 79430, USA. john.fisher@ttuhsc.edu.
Christopher GerzinaTexas Tech University Health Sciences Center (TTUHSC), 3601 4th St., Lubbock, Tx, 79430, USA.
Kaitlin RushTexas Tech University Health Sciences Center (TTUHSC), 3601 4th St., Lubbock, Tx, 79430, USA.
Cyrus CaroomTexas Tech University Health Sciences Center (TTUHSC), 3601 4th St., Lubbock, Tx, 79430, USA.
Texas Tech University Health Sciences Center · USTexas Tech University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe femoral neck system (FNS) is commonly used for internal fixation of femoral neck fractures and has shown promising results. However, we have observed cases of peri-implant subtrochanteric femur fractures associated with the use of FNS at our institution. This case series aims to investigate four cases of peri-implant subtrochanteric fractures in patients treated with the FNS implant for femoral neck fractures. CASE PRESENTATION: We reviewed 35 patients who underwent treatment with FNS for femoral neck fractures between January 2017 and December 2021 at our level 1 trauma institution. Among these patients, four cases of peri-implant subtrochanteric femur fractures were identified. In contrast, no such fractures occurred in patients treated with cannulated screws or dynamic hip screws (DHS). Interestingly, all four cases of peri-implant fractures were seen in patients with incomplete nondisplaced femoral neck fractures. Only one case involved an identifiable technical error.

conclusionsThis case series sheds light on peri-implant subtrochanteric femur fractures as a previously unreported complication associated with the use of FNS for femoral neck fractures. These fractures were observed exclusively in patients with incomplete nondisplaced fractures who received FNS fixation. No similar complications were observed in patients treated with other types of fixation. This finding suggests the need for caution and further investigation when considering FNS as a treatment option for this specific fracture pattern. The identification of peri-implant subtrochanteric femur fractures as a potential complication of FNS usage in incomplete nondisplaced femoral neck fractures raises important considerations for clinical decision-making and patient management in orthopedic trauma.

Indexed as

Femoral Neck FracturesHip FracturesClinical Decision-MakingFemurFemur NeckHumansComplication of hip fracture treatmentFemoral neck fixationFemoral neck fractureFemoral neck systemOpen reduction internal fixation femoral neckPeri-implant fractureProximal femur fractureSubtrochanteric femur fractureTrauma

Identifiers

PMID37737167
PMCPMC10514930
OpenAlexW4386944313

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.