ArticleBMC musculoskeletal disorders2023
Subtrochanteric fracture after femoral neck system of femoral neck fractures: a report of four cases.
Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.
- Comparative efficacy and safety of three internal fixation strategies for femoral neck fractures: a network meta-analysis.Frontiers in medicine · 2026Pooled it
- Clinical efficacy of personalized 3D-printed modular navigation templates in assisting Femoral Neck System implantation for femoral neck fractures in young and middle-aged adults.BMC musculoskeletal disorders · 2025Trial
- Femoral neck system versus cannulated screws combined with medial plate for femoral neck fractures in young and middle-aged patients: a prospective multicenter randomized controlled trial.Journal of orthopaedic surgery and research · 2025Trial
- Does FNS outperform CCS in Pauwel's type III fracture fixation: a combined experimental and numerical study.Medical & biological engineering & computing · 2026Article
- In silico analysis of fixation device strain patterns in the postoperative proximal femur: Effects of bone quality during gait.Clinical biomechanics (Bristol, Avon) · 2025Article
- Fatigue testing of a self-compression screw model in Pauwels III fracture: an in vitro analysis.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Article
- Simultaneous Total Hip Arthroplasty and Plate Fixation for Ipsilateral Subtrochanteric Fracture Following Femoral Neck Osteosynthesis.Case reports in orthopedics · 2025Article
- Comparison of dynamic compression system versus multiple cancellous screws in the treatment of femoral neck fractures in young adults.Journal of orthopaedic surgery and research · 2024Article
- Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis.BMC musculoskeletal disorders · 2024Article
- Biomechanical study of a biplanar double support screw (BDSF) technique based on Pauwels angle in femoral neck fractures: finite element analysis.Frontiers in bioengineering and biotechnology · 2024Article
- Femoral Neck System and Cannulated Compression Screws in the Treatment of Femoral Neck Fractures: Umbrella Review of Meta-Analyses.JB & JS open accessReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe femoral neck system (FNS) is commonly used for internal fixation of femoral neck fractures and has shown promising results. However, we have observed cases of peri-implant subtrochanteric femur fractures associated with the use of FNS at our institution. This case series aims to investigate four cases of peri-implant subtrochanteric fractures in patients treated with the FNS implant for femoral neck fractures. CASE PRESENTATION: We reviewed 35 patients who underwent treatment with FNS for femoral neck fractures between January 2017 and December 2021 at our level 1 trauma institution. Among these patients, four cases of peri-implant subtrochanteric femur fractures were identified. In contrast, no such fractures occurred in patients treated with cannulated screws or dynamic hip screws (DHS). Interestingly, all four cases of peri-implant fractures were seen in patients with incomplete nondisplaced femoral neck fractures. Only one case involved an identifiable technical error.
conclusionsThis case series sheds light on peri-implant subtrochanteric femur fractures as a previously unreported complication associated with the use of FNS for femoral neck fractures. These fractures were observed exclusively in patients with incomplete nondisplaced fractures who received FNS fixation. No similar complications were observed in patients treated with other types of fixation. This finding suggests the need for caution and further investigation when considering FNS as a treatment option for this specific fracture pattern. The identification of peri-implant subtrochanteric femur fractures as a potential complication of FNS usage in incomplete nondisplaced femoral neck fractures raises important considerations for clinical decision-making and patient management in orthopedic trauma.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.