ArticleEuropean radiology2024
Large variation in radiation dose for routine abdomen CT: reasons for excess and easy tips for reduction.
Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Identifying optimal dose head CT acquisition techniques through cluster analysis from 904,209 scans.European radiology · 2026Article
- Low-kVp techniques for radiation dose optimization in abdominopelvic contrast-enhanced CT: a scoping review.Radiological physics and technology · 2026Article
- Bowel ischemia detection on portal venous CT: multireader evaluation of dual-energy and photon-counting spectral imaging.European radiology · 2026Article
- Tips and tricks for reducing radiation exposure during retrograde intrarenal surgery: A literature review by the European Association of Urology Section of Endourology.Asian journal of urology · 2026Review
- Radiation dose has no significant impact on CT-based bone mineral density measurements in a large-animal model.Scientific reports · 2026Article
- Crowd-sourcing optimized abdomen CT protocols from 908,000 examinations in a large radiation dose registry.European radiology · 2026Article
- Quantifying Patient Positioning Errors and Radiation Dose Variation in Cardiac Computed Tomography Angiography.Journal of the Saudi Heart Association · 2026Article
- Image quality and radiation dose of reduced-dose abdominopelvic computed tomography (CT) with silver filter and deep learning reconstruction.Scientific reports · 2025Article
- So many countries, so many customs, so many ways of using CT.European radiology · 2025Article
- Optimizing DSA parameters for enhanced radiation safety in interventional surgery.Frontiers in public health · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
21 authors.
Funding
Abstract
objectiveTo characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT.
methodsWe retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation. Lastly, we modeled the total population dose if all protocols with mean size-adjusted DLP above 433 or 645 mGy-cm were reduced to these thresholds.
resultsA total of 748,846 CTs were performed using 1033 unique protocols. When sorted by patient size, patients with larger abdominal diameters had increased dose and effective mAs (milliampere seconds), even after adjusting for patient size. When sorted by size-adjusted dose, patients in the highest versus the lowest decile in size-adjusted DLP received 6.4 times the average dose (1680 vs 265 mGy-cm) even though diameter was no different (312 vs 309 mm). Effective mAs was 2.1-fold higher, unadjusted CTDI
conclusionThere are large variations in radiation doses for routine abdomen CT unrelated to patient size. Modification of kV and single-phase scanning could result in substantial dose reduction. CLINICAL RELEVANCE: Radiation dose-optimization techniques for routine abdomen CT are routinely under-utilized leading to higher doses than needed. Greater modification of technical parameters and number of phases could result in substantial reduction in radiation exposure to patients. KEY POINTS: • Based on an analysis of 748,846 routine abdomen CT scans in adults, radiation doses varied tremendously across patients of the same size and optimization techniques were routinely under-utilized. • The difference in observed dose was due to variation in technical parameters and phase count. Automatic exposure control was commonly used to modify effective mAs, whereas kV was rarely adjusted for patient size. Routine abdomen CT should be performed using a single phase, yet multi-phase was common. • kV modulation by patient size and restriction to a single phase for routine abdomen indications could result in substantial reduction in radiation doses using well-established dose optimization approaches.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.