Evidence map›Paper›PMID 37734027›Full record

ArticleACS sensors2023

Toward Personalized Treatment of Depression: An Affordable Citalopram Test based on a Solid-Contact Potentiometric Electrode for at-Home Monitoring of the Antidepressant Dosage.

Ruitong Chen, Farbod Amirghasemi, Haozheng Ma, Victor Ong, Ava Tran, Maral P S Mousavi

Open access · greenAbstract read
In one paragraph

Article in ACS sensors, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Review
  2. Diverse applications and development of aptamer detection technology.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Ruitong ChenAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90089, United States.
Farbod AmirghasemiAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90089, United States.
Haozheng MaAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90089, United States.
Victor OngAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90089, United States.ORCID 0000-0002-4564-4075
Ava TranMork Family Department of Chemical Engineering, University of Southern California, Los Angeles, California 90089, United States.
Maral P S MousaviAlfred E. Mann Department of Biomedical Engineering, University of Southern California, Los Angeles, California 90089, United States.ORCID 0000-0003-0004-7178
University of Southern California · US

Funding

Building a two-way communication system: Bio-orthogonal superhydrophobic nanoparticles for controlled stimulation and real-time sensing of neurotransmittersDP2GM150018 · NIGMS · UNIVERSITY OF SOUTHERN CALIFORNIA · PI MOUSAVI, MARAL · 2022 to 2025
$2.3M
NIGMS NIH HHS DP2 GM150018
6 · The paper itself

Abstract

Citalopram (CTLP) is one of the most common antidepressants prescribed worldwide. It has a narrow therapeutic window and can cause severe toxicity and mortality if the dosage exceeds the safe level. Reports indicated that at-home monitoring of citalopram dosage considerably benefits the patients, yet there are no devices capable of such measurement of citalopram in biofluids. This work presents an affordable citalopram test for at-home and point-of-care monitoring of citalopram levels in urine, ensuring a safe and effective drug compliance. Our platform consists of a citalopram-selective yarn-based electrode (CTLP-SYE) that uses polymeric sensing membranes to provide valuable information about drug concentration in urine. CTLP-SYE is noninvasive and has a response time of fewer than 10 s. The fabricated electrode showed near-Nernstian behavior with a 52.3 mV/decade slope in citalopram hydrobromide solutions ranging from 0.5 μM to 1.0 mM, with a detection limit of 0.2 μM. Results also indicated that neither interfering ions nor pH affects electrode performance. We showed that CTLP-SYE could accurately and reproducibly measure citalopram in human urine (RSD 2.0 to 3.2%, error <12%) at clinically relevant concentrations. This work paves the way for the personalized treatment of depression and accessible companion diagnostics to improve treatment efficacy and safety.

Indexed as

CitalopramDepressionAntidepressive AgentsElectrodesHumansPrecision MedicineAntidepressive AgentsCitalopramcompanion diagnosticsmental healthpoint-of-care sensingpotentiometrysolid-contact electrodeSSRIyarn-based sensor

Identifiers

PMID37734027
PMCPMC11446579
OpenAlexW4386915521

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.