ArticlePloS one2023
Optimizing digital implant impressions: Evaluating the significance of scan body image deficiency and alignment under varied scan body exposures.
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 6 citations in OpenAlex.
- Digital impression accuracy for bone-level and tissue-level implants using scan bodies of different heights.Scientific reports · 2025Article
- Article
- Effect of the scan body alignment process on the accuracy of virtual definitive implant casts: a pilot study.The journal of advanced prosthodontics · 2025Article
- Effect of saliva on accuracy of digital dental implant transfer using two different materials of intraoral scan bodies with different exposed lengths.BMC oral health · 2024Article
- Article
Corrections and comments
- Erratum issued
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In implant dentistry, the advent of intraoral scanning technology has revolutionized traditional clinical processes by streamlining procedures and ensuring predictable treatment outcomes. However, achieving accurate virtual implant positions using intraoral scanners and scan bodies can be influenced by various clinical and laboratory factors. This study aims to investigate the impact of scan body image capture deficiency and scan body alignment methods in computer-aided design (CAD) software on the accuracy of virtual implant positions, particularly in different implant depths. Three stereolithographic half-arch implant models with different implant depths were prepared, representing three scenarios of scan body exposure: full exposed scan body, 2/3 exposed scan body, and 1/3 exposed scan body. The scan body image capture deficiency and alignment methods were simulated using CAD software. The deviation of virtual implant positions obtained from different scenarios were evaluated using 3D analysis software. The highest angular and linear deviation (0.237±0.059 degrees, 0.084±0.068 mm) were found in the 1/4 upper and lower part scan body deficiency using the 1-point alignment method in the 1/3 exposed scan body. Two-way ANOVA analysis revealed significant effects of scan deficiency on virtual implant position deviations across all scan body exposures, except for the linear deviation when the scan body was exposed 2/3 of its length. Furthermore, scan deficiencies in the 1/4 upper and lower parts of the scan body significantly affected implant angular deviation regardless of scan body exposure, while implant linear deviation was specifically affected when the scan body was exposed to only 1/3 of its total length. Deficiencies in scan body acquisition, particularly in deep soft tissue situations, can lead to deviations in both angular and linear positioning of virtual implants. Employing appropriate scan body alignment methods such as a 3-point alignment approach demonstrates better accuracy compared to a 1-point alignment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.