Evidence map›Paper›PMID 37731426›Full record

ArticleCureus2023

Comparison of Force During the Endotracheal Intubation of Commercial Simulation Manikins.

Kate E Hughes, Md Tariqul Islam, Benjamin Co, Merryl Lopido, Neil L McNinch, David Biffar, Vignesh Subbian, Young-Jun Son, Jarrod M Mosier

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Kate E HughesEmergency Medicine, University of Arizona, Tucson, USA.
Md Tariqul IslamIndustrial Engineering, Purdue University, West Lafayette, USA.
Benjamin CoEmergency Medicine, University of Arizona, Tucson, USA.
Merryl LopidoHealth Sciences, University of Arizona, Tucson, USA.
Neil L McNinchBiostatistics, McNinch Biostats, LLC (Limited Liability Company), Kent, USA.
David BiffarHealth Sciences, University of Arizona, Tucson, USA.
Vignesh SubbianSystems and Industrial Engineering, University of Arizona, Tucson, USA.
Young-Jun SonIndustrial Engineering, Purdue University, West Lafayette, USA.
Jarrod M MosierEmergency Medicine, University of Arizona, Tucson, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background  Medical simulation allows clinicians to safely practice the procedural skill of endotracheal intubation. Applied force to oropharyngeal structures increases the risk of patient harm, and video laryngoscopy (VL) requires less force to obtain a glottic view. It is unknown how much force is required to obtain a glottic view using commercially available simulation manikins and if variability exists. This study compares laryngoscopy force for a modified Cormack-Lehane (CL) grade I view in both normal and difficult airway scenarios between three commercially available simulation manikins. Methods Experienced clinicians (≥2 years experience) were recruited to participate from critical care, emergency medicine, and anesthesia specialties. A C-MAC size 3 VL blade was equipped with five force resistor reading (FSR) sensors (four concave surfaces, one convex), measuring resistance (Ohms) in response to applied pressure (1-100 Newtons). The study occurred in a university simulation lab. Using a randomized sequence, 49 physicians performed intubations on three manikins (Laerdal SimMan 3GPlus, Gaumard Hal S3201, CAE Apollo) in normal and difficult airway scenarios. The outcomes were sensor mean pressure, peak force, and CL grade. Summary statistics were calculated. Generalized estimating equations (GEEs) conducted for both scenarios assessed changes in pressure measured in three manikins while accounting for correlated responses of individuals assigned in random order. Paired t-test assessed for the in-manikin difference between scenarios. STATA/BE v17 (R) was used for analysis; results interpreted at type I error alpha is 0.05.  Results Participants included 49 experienced clinicians. Mean years' experience was 4(±6.6); median prior intubations were 80 (IQR 50-400). Mean individual sensor pressure varied within scenarios depending on manikin (p<0.001). Higher mean forces were used in difficult scenarios (603.4±128.9, 611.1±101.4, 467.5±72.4 FSR) than normal (462.5±121.9, 596.0±90.5, 290.6±63.2 FSR) for each manikin (p<0.001). All manikins required more peak force in the difficult scenario (p<0.03). The highest mean forces (Laerdal, CAE, difficult scenario) were associated with the higher frequency of grade 2A views (p<0.001). The Gaumard manikin was rated most realistic in terms of force required to intubate. Conclusion Commercially available high-fidelity manikins had significant variability in laryngoscopy force in both normal and difficult airway scenarios. In difficult airway scenarios, significant variability existed in CL grade between manikin brands. Experienced clinicians rated Gaumard Hal as the most realistic force applied during endotracheal intubation.

Indexed as

cormack-lehane gradeexperienced cliniciansintubation forceintubation simulationsimulation trainervideo laryngoscopy (vl)

Identifiers

PMID37731426
PMCPMC10508868

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.