Evidence map›Paper›PMID 37727188›Full record

ArticleCureus2023

Diagnostic Accuracy of Portal Vein Flow Velocity for Esophageal Varices in Cirrhotic Patients.

Hafiz Muhammad Wasif Khan, Bushra Bilal, Kayenat Khan, Muhammad Osama Tariq Butt, Anas Ahmad Shah, Usman Iqbal Aujla

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hafiz Muhammad Wasif KhanDepartment of Gastroenterology and Hepatology, Pakistan Kidney and Liver Institute and Research Centre, Lahore, PAK.
Bushra BilalDepartment of Radiology, Pakistan Kidney and Liver Institute and Research Centre, Lahore, PAK.
Kayenat KhanDepartment of Radiology, Pakistan Kidney and Liver Institute and Research Centre, Lahore, PAK.
Muhammad Osama Tariq ButtDepartment of Gastroenterology and Hepatology, Pakistan Kidney and Liver Institute and Research Centre, Lahore, PAK.
Anas Ahmad ShahDepartment of Gastroenterology and Hepatology, Pakistan Kidney and Liver Institute and Research Centre, Lahore, PAK.
Usman Iqbal AujlaDepartment of Gastroenterology and Hepatology, Pakistan Kidney and Liver Institute and Research Centre, Lahore, PAK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Variceal bleeding is a life-threatening complication of cirrhosis. Traditionally, endoscopy has been utilized as a preferred modality for the detection and grading of esophageal varices. However, endoscopy is an invasive procedure and may not be readily available in resource-limited settings. To overcome this limitation, various non-invasive tests, including Doppler ultrasonography (DUS) with portal vein (PV) velocity measurement, have been investigated to predict the presence of esophageal varices (EV). This study aimed to evaluate the potential utility of portal vein flow velocity (PVFV) as a non-invasive alternative to endoscopic screening for predicting the presence of esophageal varices among cirrhotic patients. Methodology This validation cross-sectional study was carried out at the Department of Gastroenterology and Hepatology, Pakistan Kidney and Liver Institute & Research Centre (PKLI&RC), Lahore, Pakistan from June 8, 2022, to March 8, 2023. Cirrhotic patients were enrolled based on clinical, laboratory, and radiological assessments. Doppler ultrasonography was performed to measure portal vein flow velocity along other relevant indices. Subsequently, all patients underwent endoscopic evaluation to screen and grade the esophageal varices. Univariate and multivariate logistic regression analyses were performed to identify significant clinical predictors of EV based on the results of the independent sample t-tests or Mann-Whitney U tests. Receiver operating characteristic (ROC) curves were employed to determine the optimal cut-off value for portal vein flow velocity (PVFV). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated based on the identified cut-off value. A p-value ≤ 0.05 was considered statistically significant. Results A cohort of 137 cirrhotic patients was enrolled. The study population consisted of 92 males (67.2%) and 45 females (32.8%). Endoscopic screening confirmed the presence of esophageal varices in 81 patients (59.91%). A multivariate analysis revealed that aspartate aminotransferase to platelet ratio index (APRI) (p=0.008) and portal vein flow velocity (p=0.001) were significant factors associated with esophageal varices and were used for receiver operating characteristic (ROC) analysis. The area under the curve (AUC) for PVFV was 0.981, and for APRI, it was 0.711. At a cut-off value of 18 cm/sec for PVFV, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for esophageal varices were found to be 93.83%, 92.86%, 95%, 91.23%, and 93.43%, respectively. Conclusion Measurement of portal vein flow velocity using Doppler ultrasonography (DUS) is a reliable screening method for predicting the presence of esophageal varices (EV) in patients with liver cirrhosis. DUS offers several advantages, including its non-invasive nature, cost-effectiveness, and widespread availability, making it a recommended approach due to its high diagnostic accuracy.

Indexed as

cirrhosisdoppler ultrasonographyendoscopyesophageal varicesportal vein flow velocity

Identifiers

PMID37727188
PMCPMC10506378

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.