LED light can falsify pulse oximetry readings via the stroboscopic effect.

Martin Wald, Peter Erwin, Natalee Annon-Eberharter, Tobias Werther

Open access · hybridAbstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Martin WaldDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Paracelsus Medical University, University Hospital Salzburg, Salzburg, Austria. neooffice@salk.at.ORCID http://orcid.org/0000-0002-6558-1032
Peter ErwinDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Paracelsus Medical University, University Hospital Salzburg, Salzburg, Austria.
Natalee Annon-EberharterDivision of Neonatology, Department of Pediatrics and Adolescent Medicine, Paracelsus Medical University, University Hospital Salzburg, Salzburg, Austria.
Tobias WertherDivision of Neonatology, Pediatric Intensive Care and Neuropediatrics, Department of Pediatrics and Adolescent Medicine, Comprehensive Center for Pediatrics, Medical University of Vienna, University Hospital Vienna, Vienna, Austria.ORCID http://orcid.org/0000-0003-2442-8557
Paracelsus Medical University · ATMedical University of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Because of its simplicity, pulse oximetry plays a ubiquitous role in neonatology. Its measurements are based on the absorption of light by hemoglobin. Ambient light can affect these values, therefore algorithms are designed to compensate for constant ambient light. Modern light-emitting diodes often flicker at a very high frequency. Such flickering ambient light can lead to significant measurement errors in saturation. To present a novel way in which light-emitting diodes influence the function of pulse oximeters and to demonstrate mathematically that a stroboscopic effect may well be responsible for this disturbance. Using publicly available data, a mathematical model of a pulse oximeter with a calibration curve and a proprietary measurement algorithm was created. This was used to simulate saturation measurements in flickering ambient light. To do this, photopletysmograms for red and infrared light at 98% oxygen saturation were mathematically superimposed on the light emission from an examination lamp used in the intensive care unit. From these results, presumable saturation measurements from a pulse oximeter were extrapolated. The light-emitting diodes in the examination lamp flicker at 207 Hz. The pulsating light from the light-emitting diodes causes superimposition of the photoplethysmogram due to the stroboscopic effect. With increasing brightness, the saturation dropped to 85% and the pulse rate to 108 bpm. The pulsed light of light-emitting diodes can distort pulse oximetry measurements. The stroboscopic effect leads to low saturation values, which can lead to the risk of blindness in premature infants due to excessive oxygenation.

Indexed as

OximetryOxygenAlgorithmsHemoglobinsHumansInfantInfant, NewbornInfant, PrematureHemoglobinsOxygenArtifactsLight-emitting diodePulse oximetryStroboscopic effect

Identifiers

PMID37725312
PMCPMC10703953
OpenAlexW4386864784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.