ArticlePhysical and engineering sciences in medicine2023
LED light can falsify pulse oximetry readings via the stroboscopic effect.
Article in Physical and engineering sciences in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 5 citations in OpenAlex.
- Characterizing the influence of skin pigmentation on pulse oximetry.Biophotonics discovery · 2025Article
- Hospital Environmental Factors That Influence Peripheral Oxygen Saturation Measurements: A Cross-Sectional Study.Healthcare (Basel, Switzerland) · 2024Article
- Averaging Times for Pulse Oximeter Measurements - A Review of Manuscripts Published in the Top Five Sleep Medicine Journals.Nature and science of sleep · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Because of its simplicity, pulse oximetry plays a ubiquitous role in neonatology. Its measurements are based on the absorption of light by hemoglobin. Ambient light can affect these values, therefore algorithms are designed to compensate for constant ambient light. Modern light-emitting diodes often flicker at a very high frequency. Such flickering ambient light can lead to significant measurement errors in saturation. To present a novel way in which light-emitting diodes influence the function of pulse oximeters and to demonstrate mathematically that a stroboscopic effect may well be responsible for this disturbance. Using publicly available data, a mathematical model of a pulse oximeter with a calibration curve and a proprietary measurement algorithm was created. This was used to simulate saturation measurements in flickering ambient light. To do this, photopletysmograms for red and infrared light at 98% oxygen saturation were mathematically superimposed on the light emission from an examination lamp used in the intensive care unit. From these results, presumable saturation measurements from a pulse oximeter were extrapolated. The light-emitting diodes in the examination lamp flicker at 207 Hz. The pulsating light from the light-emitting diodes causes superimposition of the photoplethysmogram due to the stroboscopic effect. With increasing brightness, the saturation dropped to 85% and the pulse rate to 108 bpm. The pulsed light of light-emitting diodes can distort pulse oximetry measurements. The stroboscopic effect leads to low saturation values, which can lead to the risk of blindness in premature infants due to excessive oxygenation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.