Evidence map›Paper›PMID 37725147›Full record

Observational studyGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2024

Impact of the preoperative cylinder on astigmatism correction in femtosecond lenticule extraction (FLEX): a prospective observational study.

Xiuyu Mao, Han Chen, Yinzhen Zhao, Shunmei Ji, Jinhui Dai

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Xiuyu Mao *Department of Ophthalmology, Zhongshan Hospital Affiliated to Fudan University, Shanghai, 200032, China.
Han Chen *Department of Ophthalmology, Eye & ENT Hospital Affiliated to Fudan University, Shanghai, 200031, China.
Yinzhen ZhaoDepartment of Ophthalmology, Zhongshan Hospital Affiliated to Fudan University, Shanghai, 200032, China.
Shunmei JiDepartment of Ophthalmology, Zhongshan Hospital Affiliated to Fudan University, Shanghai, 200032, China.
Jinhui DaiDepartment of Ophthalmology, Zhongshan Hospital Affiliated to Fudan University, Shanghai, 200032, China. jinhuidai@163.com.ORCID http://orcid.org/0000-0003-3221-3150
Sun Yat-sen University · CNEye & ENT Hospital of Fudan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo explore the impact of the preoperative manifest cylinder on astigmatism correction via femtosecond lenticule extraction (FLEX), or small incision lenticule extraction (SMILE).

methodsThis was a prospective observational study. Eyes were categorized into mild (n = 88), moderate (n = 46), and severe (n = 53) astigmatism groups, based on the preoperative manifest cylinder. Vector analysis was conducted with the back vertex distance set at 12 mm. The primary outcome was the correction index (CI), with secondary outcomes including the safety, efficacy, predictability, and vectoral alterations related to FLEX.

resultsThe average target-induced astigmatism was 0.45 ± 0.20 D, 0.95 ± 0.17 D, and 1.99 ± 0.65 D in the three groups (P < 0.001), and the average CI was 1.12± 0.05, 1.01 ± 0.03, and 0.95 ± 0.02 (P = 0.020), with the severe astigmatism group displaying a notably lower CI. The efficacy, safety, predictability, or stability of FLEX did not demonstrate any significant differences among the three groups. The CIs exhibited a significant difference in eyes with with-the-rule (WTR) astigmatism and against-the-rule (ATR) astigmatism from the mild to severe astigmatism group. In eyes with oblique astigmatism, the average CI exceeded one.

conclusionPatients with manifest cylinder exceeding 1.25 D have a heightened risk of under-correction in WTR and ATR astigmatism compared to those with mild astigmatism, and mild over-correction may occur in cases of oblique astigmatism.

Indexed as

AstigmatismCorneal Surgery, LaserMyopiaCorneal StromaHumansLasers, ExcimerRefraction, OcularTreatment OutcomeVisual AcuityAstigmatism correctionFemtosecond lenticule extractionPreoperative cylinderProspective observational study

Identifiers

PMID37725147
OpenAlexW4386845063

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.