ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2023
Clinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator.
Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 16 citations in OpenAlex.
- A bibliometric and visual analysis of implantable cardioverter defibrillator use in hypertrophic cardiomyopathy: 2000-2025.Journal of cardiothoracic surgery · 2026Article
- Not Afraid to Go Beyond: Innovative Management of Intermuscular S-ICD Infection.JACC. Case reports · 2025Article
- Exploring the Current Status of Risk Stratification in Hypertrophic Cardiomyopathy: From Risk Models to Promising Techniques.Journal of cardiovascular development and disease · 2025Review
- Substrates of Sudden Cardiac Death in Hypertrophic Cardiomyopathy.Journal of clinical medicine · 2025Review
- Review
- Subcutaneous versus transvenous implantable cardioverter defibrillator in hypertrophic cardiomyopathy: a systematic review and meta-analysis.Cardiovascular diagnosis and therapy · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
18 authors at 10 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimsThe implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND
resultsConsecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521).
conclusionHypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials