Technical Feasibility of Quantitative Measurement of Various Degrees of Small Bowel Motility Using Cine Magnetic Resonance Imaging.

Ji Young Choi, Jihye Yun, Subin Heo, Dong Wook Kim, Sang Hyun Choi, Jiyoung Yoon, Kyuwon Kim, Kee Wook Jung, Seung-Jae Myung

Open access · hybridAbstract read
In one paragraph

Article in Korean journal of radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Ji Young Choi *Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-0170-171X
Jihye Yun *Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-5233-6687
Subin HeoDepartment of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-4700-1014
Dong Wook KimDepartment of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea. fsnoruen@gmail.com.ORCID 0000-0001-7887-657X
Sang Hyun ChoiDepartment of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-6898-6617
Jiyoung YoonDepartment of Gastroenterology, Uijeongbu Eulji Medical Center, Uijeongbu, Republic of Korea.ORCID 0000-0001-7448-4296
Kyuwon KimDepartment of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-1150-5819
Kee Wook JungDepartment of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0002-3771-3691
Seung-Jae MyungDepartment of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.ORCID 0000-0003-0585-4016
Ulsan College · KRThe Catholic University of Korea Uijeongbu St. Mary's Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveCine magnetic resonance imaging (MRI) has emerged as a noninvasive method to quantitatively assess bowel motility. However, its accuracy in measuring various degrees of small bowel motility has not been extensively evaluated. We aimed to draw a quantitative small bowel motility score from cine MRI and evaluate its performance in a population with varying degrees of small bowel motility. MATERIALS AND

methodsA total of 174 participants (28.5 ± 7.6 years; 135 males) underwent a 22-second-long cine MRI sequence (2-dimensional balanced turbo-field echo; 0.5 seconds per image) approximately 5 minutes after being intravenously administered 10 mg of scopolamine-N-butyl bromide to deliberately create diverse degrees of small bowel motility. In a manually segmented area of the small bowel, motility was automatically quantified using a nonrigid registration and calculated as a quantitative motility score. The mean value (MV) of motility grades visually assessed by two radiologists was used as a reference standard. The quantitative motility score's correlation (Spearman's

resultsFor the MV of the quantitative motility scores at grades 1, 1.5, 2, 2.5, and 3, the mean ± standard deviation values were 0.019 ± 0.003, 0.027 ± 0.010, 0.033 ± 0.008, 0.032 ± 0.009, and 0.043 ± 0.013, respectively. There was a significant positive correlation between the quantitative motility score and the MV (

conclusionThe quantitative motility score calculated from a cine MRI enables diagnosis of an adynamic small bowel, and potentially discerns various degrees of bowel motility.

Indexed as

Intestine, SmallMagnetic Resonance Imaging, CineFeasibility StudiesGastrointestinal MotilityHumansMagnetic Resonance ImagingMaleBowelCine imagingGastrointestinal motilityMagnetic resonance imagingSmall intestine

Identifiers

PMID37724587
PMCPMC10613842
OpenAlexW4386852365

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.