Evidence map›Paper›PMID 37724319›Full record

ArticleOman medical journal2023

Performance Comparison Between Conventional Fluorescent Spot Test and Quantitative Assay in Detecting G6PD Deficiency in Neonates.

Sarah Abdul Halim, Rosnah Bahar, Wan Zaidah Abdullah, Erinna Mohamad Zon, Shafini Mohamed Yusoff

Abstract read
In one paragraph

Article in Oman medical journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Prevalence of G6PD candidate variants in malaria-endemic populations of northern Brazil.The Brazilian journal of infectious diseases : an official publication of the Brazilian Society of Infectious Diseases
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Sarah Abdul HalimDepartment of Hematology and Transfusion Medicine Unit, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia.
Rosnah BaharDepartment of Hematology and Transfusion Medicine Unit, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia.
Wan Zaidah AbdullahDepartment of Hematology and Transfusion Medicine Unit, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia.
Erinna Mohamad ZonDepartment of Obstetrics and Gynecology, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia.
Shafini Mohamed YusoffDepartment of Hematology and Transfusion Medicine Unit, School of Medical Sciences, Universiti Sains Malaysia, Kelantan, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy worldwide. The fluorescent spot test (FST) is the conventional method for screening neonates for G6PD. However, it has limitations and quantitative assays such as the CareStart Biosensor 1 are being increasingly recommended. This study aimed to compare FST and CareStart Bioensor 1 in their ability to detect G6PD levels in neonates. Methods: This cross-sectional study involved 455 neonates between June and December 2020. Two milliliters of cord blood were analyzed with CareStart Biosensor 1 and dried cord blood spots with FST. Data was recorded and statistically analyzed. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated to determine the performance of FST at specific G6PD cut-off values; Cohen's kappa analysis assessed the agreement between the two methods. Results: The sensitivity of FST at 30% cut-off G6PD activity level was 91.0%, (95% CI: 57.0-100) and specificity of 97.0% (95% CI: 95.0-98.0). At 60% cut-off, the FST sensitivity sharply declined to 29.0% (95% CI: 19.0-40.0) with a specificity of 100% (95% CI: 98.0-100). The overall prevalence of G6PD deficiency was 5.1% as measured by FST and 17.8% by Biosensor 1 ( Conclusions: In this study, FST missed a significant proportion of cases of intermediate G6PD levels. FST also misclassified several G6PD intermediate individuals as normal, rendering them susceptible to oxidative stress. Biosensor 1 reported a significantly higher prevalence of G6PD deficiency.

Indexed as

G6PD DeficiencyPrevalenceQuantitative AssaySensitivitySpecificity

Identifiers

PMID37724319
PMCPMC10505278

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.